Anderson Greenwood ERQS Flame Arrester
Anderson Greenwood
Product Code: ERQS
Brand: Anderson Greenwood
GET OFFER: info@imtek.com.tr
Description for Anderson Greenwood ERQS Flame Arrester
1. GENERAL ERQ series vent flame arresters are intended for low-pressure venting applications where the maximum differential pressure across the flame arrester does not exceed 1 barg. 2. GUIDANCE 1. Maximum temperature limit is -20° to +60°C (+200°C for certain gas groups - see special conditions for safe use). 2. Mounting of all monitoring devices shall be in accordance with EN 50018. 3. Flame arresters should not be positioned near hot equipment unless certified for the elevated temperature as heat transfer to the flame arrester will reduce its performance and may cause it to fail. 4. Shut-off devices should be fully open during normal operation. 5. Continuous monitoring of pressure drop is advised if the process is known to contain particulates or substances which can block the element and over-pressurize the system. 6. Metal parts insulated by gaskets should be earthed where necessary. 7. Flame velocities and pressures of flammable mixtures can be enhanced by upstream turbulence, which can be caused by bends, valves or any change in section of the pipework. The flame arrester should only be used for the process application; if the process conditions or the pipework configuration change the flame arrester should be checked with the manufacturer. 8. ERQ series vent flame arresters are designed to prevent external fires/ explosions igniting flammable gases/ vapors within vent piping and associated equipment. They are NOT designed to prevent internal explosions passing to atmosphere. 9. ONLY install for applications for which they have been designed and specified - refer to product data sheet for guidance. It is potentially dangerous to use in other applications.3. INSTALLATION Remove all packaging from the flame arrester prior to installation, paying particular attention to the area between the flame arrester element and weather cover. Mount the flame arrester vertically upright at the end of the vent line: (i) Flanged connection - bolt to a flange of the same specification as that fitted to the flame arrester itself, with an intermediate gasket of a type appropriate to the service conditions. Tighten the bolting uniformly to ensure a good seal. (ii) Screwed connection - fit to the corresponding male/female thread. Sealing tape or sealant may be used to ensure a good seal.Recommended Products For Anderson Greenwood