Aoip CALYS 100 Field Instruments
Aoip
Product Code: CALYS 100
Brand: Aoip
GET OFFER: info@imtek.com.tr
Description for Aoip CALYS 100 Field Instruments
CALYS 100 is a field precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument.Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…), CALYS 100 makes advanced data exploitation and full data traceability easier, as well as quick access to functions by menus.The instrument simultaneously measures and simulates:Temperature: Up to 0,012% RDGResistance: Up to 0,010% RDG, 4 K? rangeCurrent: Up to 0,012% RDG, 50 mA range + 24 V loop supplyVoltage: Up to 0,010% RDG, 50 V rangeFrequency: Up to 0,005% RDG, 20 KHz range (10 KHz in simulation)Pressure: When used with an external pressure module (ref. ACL433), CALYS 100 can measure and simulate pressure (comparison calibration with a pressure pump). Using this user-friendly instrument, calibration tasks can be quickly carried out over the whole process chain. Take the 900 g documenting process calibrator to the field with you during the whole week with 10 calibration procedures stored in the device. Run the procedure after connecting the probes to the instrument (Easy connect system®) and save the results for onsite easy and quick calibration.Back to the office, you can then upload the data on a computer in order to issue customized calibration certificates with dedicated calibration software DATACAL. IP 54, fully protected by an antichoc rubber holster, CALYS 100 integrates "easyconnect" terminals and a wide backlite display that makes it easy to use in any severe or dark conditions.Easy connection system®Connect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors.Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples. This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top. CALYS series, 4 models from basic use to advanced performances Specifications CALYS 50 CALYS 75 CALYS 100 CALYS 150 Top accuracy 200 ppm 130 ppm 50 ppm Temperature accuracy Thermocouples (14) RTDs (12) 0.013% RDG for Tc K 0.012% RDG 0.01% RDG for Tc K 0.01% RDG 0.005% RDG for Tc K 0.006% RDG DC current + Loop supply 24 V Range Accuracy 50 mA 0.0175% RDG 100 mA 0.007% RDG DC voltage Range Accuracy 50 V IN / 20 V OUT 0.013% RDG 50 V 0.013% RDG 50 V 0.010% RDG 50 V 0.005% RDG Frequency Range Accuracy 20 KHz IN / 10 KHz OUT 0.005% RDG 100 KHz 0.01% RDG Resistance Range Accuracy 4000 ? 0.012% RDG 4000 ? 0.010% RDG 50 K? 0.006% RDG Pressure Range Accuracy Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG Compliance to standards 21 CFR Part 11 NADCAP Heat treatment AMS 2750 Additional functions Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function Additional functions Switch test Calibration of transmitters Additional functions Comparison calibration HART: Digital calibration and data transfer Calibration of thermistors Software DATACAL calibration software for configuration and data management Memory 10,000 data stored and recalled on screen as curve or listRecommended Products For Aoip
Eurotherm 2404/CC/VH/H6/DL/W2/DH/XXX/FE/XX/GER/XXXXX/XXXXXX/K/0/1200/C/S2/SR/XX/XX/XX/XX/XX/ Controller Eurotherm 2404/CC/VH/H6/DL/W2/DH/XXX/FE/XX/GER/XXXXX/XXXXXX/K/0/1200/C/S2/SR/XX/XX/XX/XX/XX/ Controller
Alfa Laval 9612628129 LKB ISO SMS MALE/WELD-76.1 EPDM 304L BUTTERFLY VALVE KIT WITH 2 POSITIONS HANDLE