Aoip CALYS 75 Field Documenting Multifunction Calibrator


Aoip CALYS 75 Field Documenting Multifunction Calibrator Image

Are you interested in the product Aoip CALYS 75 Field Documenting Multifunction Calibrator from manufacturer Aoip with code CALYS 75? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!

Get Offer With E-Mail: info@im-tek.com
Get a offer for Aoip CALYS 75 Field Documenting Multifunction Calibrator from our live support team now!

CALYS 75 is a field documenting multifunction calibrator of high accuracy within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument.Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…), CALYS 75 makes advanced data exploitation and full data traceability easier, as well as quick access to functions by menus.The instrument simultaneously measures and simulates:·         Temperature: Up to 0,014% RDG·         Resistance: Up to 0,012% RDG, 4 K? range·         Current: Up to 0,0175% RDG, 50 mA range + 24 V loop supply·         Voltage: Up to 0,013% RDG, 50 V range·         Frequency: Up to 0,005% RDG, 20 KHz range (10 KHz in simulation)·         When used with an external pressure module (ref. ACL433), CALYS 75 can measure and simulate pressure (comparison calibration with a pressure pump). Using this user-friendly instrument, calibration tasks can be quickly carried out over the whole process chain. Take the 900 g documenting process calibrator to the field with you during the whole week with 10 calibration procedures stored in the device. Run the procedure after connecting the probes to the instrument (Easy connect system®) and save the results for onsite easy and quick calibration. Back to the office, you can then upload the data on a computer in order to issue customized calibration certificates with dedicated calibration software DATACAL. IP 54, fully protected by an antichoc rubber holster, CALYS 75 integrates "easyconnect" terminals and a wide backlite display that makes it easy to use in any severe or dark conditions.Easy connection systemConnect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors.Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples.This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top.  CALYS series, 4 models from basic use to advanced performances Specifications CALYS 50 CALYS 75 CALYS 100 CALYS 150 Top accuracy 200 ppm 130 ppm 50 ppm Temperature accuracy Thermocouples (14) RTDs (12) 0.013% RDG for Tc K 0.012% RDG 0.01% RDG for Tc K 0.01% RDG 0.005% RDG for Tc K 0.006% RDG DC current + Loop supply 24 V Range Accuracy 50 mA 0.0175% RDG 100 mA 0.007% RDG DC voltage Range Accuracy 50 V IN / 20 V OUT 0.013% RDG 50 V 0.013% RDG 50 V 0.010% RDG 50 V 0.005% RDG Frequency Range Accuracy 20 KHz IN / 10 KHz OUT 0.005% RDG 100 KHz 0.01% RDG Resistance Range Accuracy 4000 ? 0.012% RDG 4000 ? 0.010% RDG 50 K? 0.006% RDG Pressure Range Accuracy Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG Compliance to standards 21 CFR Part 11 NADCAP Heat treatment AMS 2750 Additional functions Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function Additional functions Switch test Calibration of transmitters Additional functions Comparison calibration HART: Digital calibration and data transfer Calibration of thermistors Software DATACAL calibration software for configuration and data management Memory 10,000 data stored and recalled on screen as curve or list