im-tek.com

Aoip MEDUSA 510 Large Volume Portable Dry Block, Liquid Bath, Blackbody Source & Fixed Point System

Aoip

Product Code: MEDUSA 510
Brand: Aoip



GET OFFER: info@imtek.com.tr

Description for Aoip MEDUSA 510 Large Volume Portable Dry Block, Liquid Bath, Blackbody Source & Fixed Point System

Medusa 510 calibrates temperature probes from 30°C to 550°C, in three zone control of the substantially large calibration volume, 45 mm diameter by 285 mm deep. It can be used as a dry block, a liquid bath, as a blackbody source and as an ITS-90 fixed point system with calibration uncertainties as small as 0.001°C`. In addition to the main heating zone, there are additional top and bottom heaters which compensate for the end losses creating a constant temperature zone across the well.For comparison calibration, Medusa 510 should be used with an insert, the standard one has six 8 mm holes of 250 mm deep. Also available is an insert of 44 mm diameter x 170 mm deep which is suspended from the top of the block so that the height is user adjustable.Medusa 510 is available in two models, the BASIC (B) and the SITE (S).The B model includes a sophisticated temperature controller with a dual display for set temperature and dry block temperature.The S model additionally includes an in-built temperature digital indicator to which an external temperature sensor can be connected, giving greater accuracy eliminating temperature gradient and loading errors. The S model has universal sensor input allowing platinum resistance thermometers, thermocouples (Types K, N, R, S, L, B, PL2, T, J and E) along with Linear Process Inputs including to be displayed on the inbuilt indicator. The indicator can be programmed with up to five calibration points to provide high accuracy digital probe matching. The indicator and controller are both addressable over the communications link.Also included in the Site model is a timer which can set the bath between two temperatures, and automate ITS-90 fixed point operation. For surface sensor and Blackbody use, an external thermometer is recommended.For laboratory accuracy, Medusa 510 can be used with high-end temperature indicator.Key features:Large calibration volume: 48 x 285 mm deepWide temperature operation: 30°C to 550°CUse for comparison and Fixed Point calibrationUse with very long thermometersTemperature range30°C to +550°CAbsolute stability over 30 min:Dry blockBlackbody sourceSurface sensor calibrationITS-90 Fixed Point±0.03°C±0.1°C±0.5°C±0.001°CCooling time550°C to 30°C: 5 hHeating time30°C to 550°C: 90 minCalibration volume45 x 285 mm depthStandard insert6 holes: 8 mmDepth: 250 mmGeneral specificationsSize430 x 310 x 300 mmWeight17 kgDisplayResolution: 0.01 to 99.99 and 0.1 to 100.0 / 650.0Units: °C, °F, KPower supply108 / 130 V (50 / 60 Hz) or 208 / 240 V (50 / 60 Hz)1000 WattsCommunication portsRS 232

Recommended Products For Aoip


Aoip CALYS 80 IS ATEX Documenting Multifunction Calibrator
Aoip RAYOMATIC 16 Miniature 8-14 µm Process Infrared Thermometer
Aoip 944 True Surface Temperature Measurement System
Aoip CALYS 80 IS Field Instruments
Aoip RN 5306 Onsite Pyrotechnical Safety Ohmmeter
Aoip CALYS 80P IS Field ATEX Pressure Calibrator
Aoip FRONTDAQ 20 High Speed Acquisition
Aoip MICRORAY NXT Basic 8-14 µm Portable Pyrometer - Ideal for HVAC Applications
Aoip FAST-CAL MEDIUM Basic Fast Industrial Calibration
Aoip OM 22 Industrial Benchtop Micro-Ohmmeter
Aoip CALYS 1000 Benchtop Instruments
Aoip HYPERION Temperature Thermometers
Aoip 935 Semi Standard Platinum Resistance Thermometer
Aoip CRIT 100 Insulation Tester
Aoip CALYS 120 IS Multifunction Calibrator
Aoip DATACAL Calibration Software
Aoip MICROK 3-channel Expandable Precision Thermometer
Aoip CALYS 50 Field Multifunction Calibrator For Basic Use
Hydropa DS-507/F-100 Pressure Switch
Micro Detectors TH2 / E-KIC Safety
Scherzinger 3050-070-DM-55-2-Exe Titanium Gear Pumps 3050
Sitema KFHSR 18 KFHSR 018 70 Locking Unit
Martens MLR120 Evaluation Electronics
SKF 7013 CB/P4AL Ball Bearing
Alfa Laval 9613360532 UNIQUE SSV 76/3 INCH 300 W 0.8/BLASTED EPDM SHUT OFF NC ASEPTIC
Italvibras MTF 3/65-S02 600375 Electric Vibrator with Top Mounting Flange
AEP FT2 Load Cell Transducers
Gefran LT-B-0550-S L000X000A0N Potentiometer
AKH UHMF Series Main Drive Motors
KSB ETN 050-032-1251GI CP1CGA2 B Pump
Sitema KB 110 SK 110 032 Locking Unit
Anderson Greenwood RA TANK BLANKETING REGULATOR
Wilkerson F18-C4-SK00 Particulate Filter
Gefran LT-F-0130-P L000X000B00 Potentiometer
Greisinger GMH3695 Air Oxygen Measuring Device
Imtron UT125 Universal Transducer
MBS MLW 139 27 18 1 3000 Sanitary Mixflo Multitube
Alfa Laval TE67E211111230 PT: 0 to 1 bar 0,1% FS Clamp 1½",plug M12,N/A
Gefran LT-M-0700-S L000X000B00 Potentiometer
Stahl 8150/5-0800-1600-300-3321 Control and Distribution Box
Eaton Vickers (Danfoss) XG2V 8CW 10 Valve
Hydroleduc MA Series (SAE version) Fixed Displacement Hydraulic Piston Motor