Gestra
Gestra LRS1-7
استفسر عن المخزون
تواصل معنا! 24 ساعة عمل (باستثناء عطلات نهاية الأسبوع والعطلات الرسمية) لتأكيد حالة المخزون ووقت التسليم المتوقع.
Gestra
توصيل سريع من ألمانيا إلى جميع أنحاء العالم
تواصل معنا! 24 ساعة عمل (باستثناء عطلات نهاية الأسبوع والعطلات الرسمية) لتأكيد حالة المخزون ووقت التسليم المتوقع.
Description The conductivity switch LRS 1-7 in conjunction with the conductivity electrode LRG 16-9 constitutes a conductivity monitoring and control system. The electrical conductvity of n Condensate, n Boiler feedwater, n Cooling and cleaning water, n Boiler water is monitored. In steam boiler plants the conductivity monitoring & control system is used as limit switch and continuous blowdown controller.
Technical Data Type approval TÜV.WÜL.xx-014 Supply voltage 230 V, +10/–15 %, 50-60 Hz 115 V, +10/–15 %, 50-60 Hz (option) Input 1 Input for conductivity electrode LRG 16-9 Output 3 volt-free relay contacts, max. contact rating for switching voltages 115 V AC and 230 V AC: resistive/inductive 4 A. Provide contactor with interference suppressor (RC combination). Contact material: AgNi 0,15. 1 Current output 4-20 mA as actual value output, max. load 500 ? Measuring range 0.5 to 10000 µS/cm at 25 °C or 0.25 to 5000 ppm at 25 °C.
Setpoint
adjustable between 0.5 and 9999 ?S/cm or
0.25 to 5000 ppm
MAX limit
adjustable between 0.5 and 9999 ?S/cm or
0.25 to 5000 ppm
Correction factor
adjustable between 0.05 and 5,000, adjustable in
increments of 0.001
Temperature coeffizient Tk
0.0 – 3.0 % per °C, adjustable in increments of 0.1
Actual value output
4 mA corresponds to 0.5 ?S/cm
20 mA corresponds to 10, 200, 500, 1000, 6000,
9999 ?S/cm or 5, 100, 250, 500, 3000, 5000 ppm,
final values adjustable
Purging interval
(continuous blowdown valve is forced to open)
adjustable between 1 h and 24 h in increments of 1 h.
Duration of purging
adjustable between 1 min. and 6 min. in increments of 1
min.
Switching hysteresis
Controller output: – 10 % of the adjusted setpoint W,
Limit MAX: – 3 % of the adjusted MAX limit
Indicators and adjustors
1 four-digit, seven-segment indicator, red, for indicating
the actual value / setpoint and for status and error messages
2 amber LEDs for indicating actual value (X) / setpoint (W)
1 red LED for indicating MAX limit
2 green LEDs for indicating valve OPEN / CLOSED
4 pushbuttons for value and parameter settings