im-tek.com

Ayvaz AFBT Flash Vessel Tank Systems

Ayvaz

Product Code: AFBT
Brand: Ayvaz



GET OFFER: info@imtek.com.tr

Description for Ayvaz AFBT Flash Vessel Tank Systems

Things To Be Careful About Choosing Flash Vessel Tank: Saturated steam, which evaporates from the heat transfer surfaces, is converted into condensate at the same pressure. The enthalpy of saturated water at 1 bar pressure is 505 kJ / kg. If the condensate at 6 bar pressure is released by 1 bar the energy output will be 697-505 = 192 kJ / kg. This energy evaporates some of the condensate to steam.This steam is Flash Steam.Why Flash Steam is Important?It includes too much energy and it can be mount to different installation areas.If Flash Steam drains to the atmosphere there will be waste energy and effeciency lost.Acquiring Flash SteamWhen the water is heated under atmospheric pressure, the temperature rises up to 100 °C.The heat to be given does not increase the temperature, but it converts water to steam.The heat absorbed by the water during the rising of the temperature to the boiling point is called "sensible heat" or “saturated liquid heat”. At the same temperature, the heat required to turn the water at the boiling point into steam is called "latent heat".The amount of heat required to increase 1 kg of water temperature by 1 ° C in the atmospheric pressure is 4,186 kJThe saturated liquid temperature of the condensate at steam temperature and pressure of 8 bar is 721 kJ / kg (saturated steam table).If this condensate is leaked to a 2 bar tank, the heat value (saturated liquid temperature) drops to 504 kJ / kg.This is 721-504 = 217 kJ/kg of excess condensate. The percentage of the condensate to be transformed into the steam can be calculated as follows.% Flash Steam = (Q1-Q2 / q) x100Q1: Saturated liquid heat at high pressure before dischargeQ2: Saturated liquid heat of the condensate at low pressureq: The latent heat of the steam at low pressure where the condensate is drained % Flash Steam = (721-504/2201)x100 = 9.6%That is, if there is a condensate of 3000 kg;Flash Steam = 3000x9,6% = 288 kg/hFlash Steam Tanks are used to separate the flash steam from the condensate water.In order for the flash steam to move towards the top outlet at the correct speed, the diameter of the steam tank must be appropriate. This speed is about 3-5 m/s and the velocity at which water droplets can reach the bottom of the tank. In order to be efficient, the condensate inlet to the tank should be one-third of the tank neck below. The diameter of the flash steam tank should be a diameter that allows the passage of the condensate without coming into turbulence.If the difference between high and low pressure is small.The amount of steam is less than the amount of condensate. Flash steam outlet pipe selecting the diameter according to the speed will cause the tank to remain small. in which case the tank must be selected to be two diameters larger.Choosing Flash Vessel1- Maximum condensation amount is required to obtain maximum flash steam.For this reason, the capacity of steam traps must be selected carefully, taking into consideration the counterpressure. It should also be noted that in systems where temperature control valves are used, the valve will be closed and the pressure will drop.2- The amount of use of flash steam systems must be equal to the amount of flash steam.Steam can be provided by pressure drop from a higher pressure steam line when the flash steam is missing. If flash steam is excessive, some of the flash steam must be thrown out. Also, since the flash used in heating will not be needed in summer, a heat recovery system will not be necessary.Therefore, the amount of flash steam required must be prepared.3- It is beneficial if the system to be used with flash steam is close to the outlet of the condensate at high pressure. The transport of low-pressure condensate requires large diameters and will increase investment costs. In addition, the heat losses that will occur on large pipe diameters will reduce the benefits of flash buckets.

Recommended Products For Ayvaz


Ayvaz AELB-12 Level Switch
Ayvaz DKK-10 Rubber Expansion Joint with Double Sphere
Ayvaz HA-52 Air Eliminator
Ayvaz VIB-FLEX Anti Vibration Hoses
Ayvaz TDK-45 Thermodynamic Steam Trap
Ayvaz MAC5 Cable Float Switch
Ayvaz MG-33 Magnetic Level Gauge
Ayvaz C-2 Level Switch
Ayvaz PKV-50 Pneumatic Controlled On-Off Valve
Ayvaz TGV–25 FULL BORE BALL VALVE
Ayvaz GV-16 Globe Valve
Ayvaz KV-10 Butterfly Valve
Ayvaz DBKF-30 External Pressurized Expansion Joint
Ayvaz V-TYPE Braided Loop Joint
Ayvaz V-3T Ball Valve
Ayvaz TKK-2N Thermostatic Steam Trap
Ayvaz CV-20 Check Valve
Ayvaz C-4 Level Switch
Vulcanic 2116-27 Screw Plug Immersion Heater
American Industrial AA-1660-FP Heat Exchanger
Gefran PC-H-0175 0000X000D00 Potentiometer
Alfa Laval LKH-50/205 18.5KW 50HZ 230D/400-415Y SMS FSS C/SIC EPDM BLASTED SCREW LEGS/SHROUD 9614357963 Pump
Gefran LT-B-0650-P 0000X000A00 Potentiometer
Stenflex Type SA-10 DN 900 Expansion Joint
Gefran LT-H-0130-S L000X000X0N Potentiometer
ETP CLASSIC 1 ¼’’ Hub-Shaft Connection
Gefran LT-H-0075-S 0000X000B0N Potentiometer
Anderson Greenwood H1 Hand Valves (Standard)
Bollfilter 2208927
Scherzinger 4030-450-DM-25-8-Exe Stainless Steel Gear Pumps 4030
Parker 15P210QBPKS122 Duplex Filter
Nuovafima 1.M2.1.A.E.---.AAE3.41M.01D GAUGE
Gefran LT-F-0475-S 0000X000A00 Potentiometer
VIMARC CDP 300-8 Vibrator motors
Eurotherm Epack-1Ph/80A/500V/Xxx/V2/Xxx/Xxx/Tcp/Xxx/Xxxxx/ Nominal Current Eurotherm Epack-1Ph/80A/500V/Xxx/V2/Xxx/Xxx/Tcp/Xxx/Xxxxx/ Nominal Current
Koso 536HS Pressure Switches-Transmitters
Hengstler RI58-O/10000AK.72TB Encoder
Fisher DMA/AF Variable Geometry Attemporator
KSB MCPK125-080-250 FF MP2 A Pump
Dynisco MDT 462F 1/2 3.5C 15/46 Melt Pressure Transmitters
American Industrial AB-1210-TP Heat Exchanger
Koso 107AL Differential Pressure Switches and Transmitters