Barksdale Series 443, 445, 446 Intrinsically Safe Transducer
Barksdale
Product Code: Series 443, 445, 446
Brand: Barksdale
GET OFFER: info@imtek.com.tr
Description for Barksdale Series 443, 445, 446 Intrinsically Safe Transducer
Barksdale's 440 Series Intrinsically Safe Transducers provide high accuracy pressure measurement when operating in Class I, Division I environments. Intrinsically safe transducers prevent personal injury and machinery damage by preventing the explosion in the first place. External zener barriers are required in order to meet UL requirements for an intrinsically safe installation. The higher cost of having to install a zener barrier is offset with the comfort of knowing that an explosion will not occur within normal operating conditions. Three models are available: Series 443 (0-5V), Series 445 (4-20mA) and Series 446 (0-10V).General Specifications*Accuracy (LH & R):±0.25% FSO at 75°F (±0.5% for vacuum only [-23]) typicalLong Term Stability:±0.5% FSO of calibration curveTypical Life Cycle:100 million cyclesProof Pressure:2 times rated pressure or 13,000 psi max. (884 bar), whichever is lessInput:443:446:445:Excitation voltage: 11 to 28 VDCExcitation voltage: 14 to 28 VDCExcitation voltage: 12 to 28 VDCSupply Current:3.0 mA maximum (no load)Output:443:446:445:Output: 0.5 to 5.5 VDCFull scale output: 5.0 VDC ± 0.8%Zero output: 0.5 VDC ± 0.4%Output: 1 to 11 VDCFull scale output: 10 VDC ± 0.4%Zero output: 1.0 VDC ± 0.2%Output: 4 to 20 mAFull scale output: 16 mA ± 1%Zero output: 4 mA ± 2%Wetted Parts:17-4 PH (fitting) & 300 stainless steel (sensor)Enclosure:NEMA 4, 300 series stainless steelResponse Time:2 kHzPressure Connection:1/4”-18 NPT maleElectrical Connection:3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground (standard).Temperature Ranges:Operating:Compensated:Storage:-40° to 158°F (-40° to 70°C)-40° to 158°F (-40° to 70°C)-40° to 185°F (-40° to 85°C)Temperature Shift:Zero & Span:0.01% per °F over compensated range referenceVibration:15 g’s, 10-2000 Hz, MIL-STD 202Shock:50 g’s, 11 mS, MIL-STD 202 Method 213, Cond. G.Approvals: 445 only:Intrinsically safe pressure transducers are UL and cULus approved as telemetering equipment for use in hazardous locations (UL File E146589, WYMV, WYMV7) as follows:Class I, Div. 1, Groups A, B, C & DClass II, Groups E, F & G, when installed in accordance with control drawing 272148 (443); TD-B77 (445); 272147 (446).ATEX/IECEx Certification:CE 0081 Ex II 1 G D, Ex ia IIC T4 Ga,Ex ia IIIC T135°C Da, -40°C to 70°C,DEMKO 09 ATEX 143402, IECEx UL 13.0069Weight:443 & 446:445:7.4 oz. (221 grams) to 1000 psi9.9 oz. (281 grams) 2,000 psi and higher7.4 oz. (210 grams) to 1000 psi9.4 oz. (266 grams) 2,000 psi and higherWarranty:1 year warranty* See product confi gurator for additional options.Wiring CodeMILLIVOLT SERIES - 443 & 446(T4/T5)(H3/H5)Signal1Red+ Excitation3White+ Output2BlackCommon4BareCase DrainMILLIAMP SERIES - 4451Red+ Excitation2Black- Excitation4BareCase DrainRecommended Products For Barksdale
Goldammer NTR 85-SR40-T1-A-FE-L370-01-L1/250/S-T40Ö-III-M12 Level - Temperature - Capillary tube – Regulator