Barksdale Series 450 Intelligent Transmitter
Barksdale
Product Code: Series 450
Brand: Barksdale
GET OFFER: info@imtek.com.tr
Description for Barksdale Series 450 Intelligent Transmitter
Barksdale Intelligent Transmitters (BiT), Series 450 is a high pressure transmitter with HART® communication protocol option. HART® enabled sensors can communicate over the legacy two-wire 4-20 mA analog current loops offering smart features like transmitter diagnostics, calibration, and field re-ranging up to 10 times less than calibrated full scale output (10:1 turndown ratio). Three models are available: Series H455, 4-20 mA output with HART® Comm. Protocol; Series 455, 4-20 mA output; Series 452, 1-5 VDC output. These models can be configured with 24-standard pressure ranges from vacuum to 30,000 psi and multiple process connections from 1/4” NPT to 7/16” SAE and HF4 Autoclave high-pressure connections. Multiple electrical connections are also offered, including popular industrial and MS style connectors for easy connection. Series 450 offers cULus approval for ordinary location.General Specifications*Accuracyincluding Linearity,Hysteresis and Repeatability:at 75°F, Typical±0.1% of Calibrated FSO (Option [–A1])±0.25% of Calibrated FSO (Standard)±0.5% of Calibrated FSO (Vacuum only [-23])Temperature Shift:Zero & Span: 0.0125% Per °F over the compensated temperature rangeLong TermStability:closure rating:±0.2% FSO /year of calibration curveTypical Life Cycle:100 million cyclesProof Pressure:2X range for up to 7500 psi models1.5X range for 7500 - 30000 psi modelsInput:H455:455*:452*:Excitation voltage: 9 to 30 VDCExcitation voltage: 9 to 30 VDCExcitation voltage: 12 to 30 VDC* (SELV, PELV), Class II Power SupplySupply Current:H455 & 455:452:20mA max.20mA max.Output:H455:455:452:Output: 4–20 mA with HART® ProtocolFull Scale Output: 20 mA ±1%Zero output: 4 mA ±1%Output: 4–20 mAFull Scale Output: 20 mA ±1%Zero output: 4 mA ± 1%Output: 1–5 VDCFull scale output: 5.0 VDC ± 1%Zero output: 1.0 VDC ± 1%DynamicResponse Time:H455:455 & 452:<70 milliseconds<50 millisecondsEnclosure:All welded 300 series stainless steel. IP66 & IP67and NEMA 4X rated. 316 Stainless Steel (optional)Wetted Parts:Sensor:Fitting:17-4 PH Stainless steel (more than 10k psi)316L Stainless steel (up to 10k psi)Inconel (optional: up to 10k psi)17-4 PH Stainless Steel for -UL option (10k psi)17-4 PH Stainless steel (all ranges)316L Stainless steel and 718 Inconel (optional: up to10k psi)MediaGeneral:Corrosive and Acidic:(up to 10,000 psi)Gas, vapor, liquid and viscous fluids [-Z17]718 Inconel wetted material, NACE [-NC]; and 316LStainless Steel, NACE [-SS]Pressure Connection:13 available options. Refer to product configuratorfor available connections and ranges.Electrical Connection:3 conductors for voltage output series and 2conductors for current output series, 18 AWG, 80”(2 m) long with integral strain relief and case ground(standard). Jacketed cable (optional). Halogen freewires and cable.Temperature Ranges:Operating (Ambient):Compensated:Media:Storage:-40 to +176 °F (-40 to +80 °C)0 to +165 °F (-18 to +74 °C)-40 to +176 °F (-40 to +80 °C)-40 to +185 °F (-40 to +85 °C)Vibration:10 g’s, 10-500 Hz, MIL-STD 202, Method 204, Cond. AShock:50 g’s, 11 mS, MIL-STD 202 Method 213, Cond. G.Approvals:cULus:cULus approved for ordinary locations(UL 61010-1)HART® Protocol:Turndown Ratio:Analog OutputCalibration:Sensor Trim:Diagnostics:HART® 7.610:1 (Full scale output rangeability)Adjustable zero and span of 4-20mA.Full scale range must be ? (calibratedspan / 10)Sensor zero and full scale trimTransmitter failure indicated by off-scaleanalog signals to alarm the userSee HART Installation and OperationManual 272438 for detailed informationCompliances:CE, CRN (refer to drawing # 272479 for applicable models)NACE (316L SS or 718 Inconel wetted material)ElectromagneticCompatibility (EMC)IEC/EN 55011:IEC/EN 61000-4-2:IEC/EN 61000-4-3:IEC/EN 61000-4-4:H455:455 & 452:IEC/EN 61000-4-5:H455:455 & 452:IEC/EN 61000-4-6:Emission & radiated emission for class AlimitsElectrostatic discharge (ESD) test - contactdischarge +/-4 kV, Air discharge +/-8 kVRadiated RF, EM field immunity80mhz-1ghz, 3v/MEFT (Burst) Test, +/-2 kVEFT (Burst) Test, +/-1 kVSurge Test, +/-1kV betweenline and earth groundSurge test not applicable; Class II powersupply used at input of the deviceRF Immunity, 150 kHz – 80 MHz, 3VWeight:16 Ounces (453 grams)Warranty:1 year warrantyRecommended Products For Barksdale