Product Name: Bartec 17-9Z62-0002 RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM
Brand: Bartec
Product Code: 17-9Z62-0002
Tags: Bartec
RESISTIVE COUPLING 1KOHM-10KOHM
Bartec 17-9Z62-0002 RESISTIVE 1KOHM-10KOHM
Bartec 17-9Z62-0002 COUPLING ELEMENT
17-9Z62-0002 COUPLING 1KOHM-10KOHM
Bartec RESISTIVE ELEMENT 1KOHM-10KOHM
Bartec 17-9Z62-0002 RESISTIVE
COUPLING 1KOHM-10KOHM
Bartec 1KOHM-10KOHM
Bartec 17-9Z62-0002 1KOHM-10KOHM
Bartec 17-9Z62-0002 COUPLING
Bartec ELEMENT 1KOHM-10KOHM
17-9Z62-0002 RESISTIVE 1KOHM-10KOHM
Bartec 17-9Z62-0002 ELEMENT 1KOHM-10KOHM
Bartec RESISTIVE COUPLING ELEMENT
17-9Z62-0002 RESISTIVE COUPLING 1KOHM-10KOHM
RESISTIVE 1KOHM-10KOHM
Bartec RESISTIVE COUPLING 1KOHM-10KOHM
17-9Z62-0002 COUPLING
ELEMENT
RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM
Are you interested in the product Bartec 17-9Z62-0002 RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM from manufacturer Bartec with code 17-9Z62-0002? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!
Get Offer With E-Mail: info@im-tek.com
Get a offer for Bartec 17-9Z62-0002 RESISTIVE COUPLING ELEMENT 1KOHM-10KOHM from our live support team now!
DescriptionThe resistive coupling element is used to monitor open and short circuits in isolator amplifier circuits controlled by mechanical contacts. The coupling element is installed directly to the control contact or inside its terminal box.FunctionNumerous isolator amplifiers can monitor the connected sensor line for open or short circuit conditions thanks to the employment of electronic proximity switches to which current can be applied in both damped and undamped status (DIN EN 60947-5-6). Current values outside the specified range are identified as open or short circuits. If simple mechanical contacts are used, it is not possible to identify a short circuit.Neither can be distinguished between open circuit and open contact. This problem can be solved by installing a resistor combination at the end of the sensor line immediately before the switch. This combination provides a closed-circuit current even when the contacts is open. At closed contact it restricts the current to a value which lies clearly below the response threhold for short circuit.Four states can be detected:open circuit (broken cable)open switchclosed switchshort circuitThe resistive coupling element can be used with all isolator amplifiers featuring open and short circuit monitoring, e. g. BARTEC, CEAG, Hartmann & Braun, Pepperl + FuchsTechnical data *Dimensionssee data sheetStorage temperature-40 °C to +70 °CVoltagemax. DC 20 VPower2.4 W at T5Resistance1 k?/0.6 W10 k?/0.6 WConnectionTerminals: 1,5 mm²Connection cable: 0,75 mm²*Refer to the documentation for more detailed information