im-tek.com

Biolab Miniflash Touch Flash Point Analyzer

Biolab

Product Code: Miniflash Touch
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab Miniflash Touch Flash Point Analyzer

MINIFLASH TOUCH is a uniquely designed flash point tester for the determination of flashpoints of liquids and solids, using the Grabner flash point detection method of measuring the instantaneous pressure increase inside the continuously closed chamber, triggered by an energy-controlled electric arc. Heating the test chamber from the top avoids condensation of high volatile compounds, significantly improving the test results. Its continuously closed cup design and small sample volume of only 1-2 mL offers maximum safety, avoids offensive fumes in the testing area and reduces sample waste. The fast thermoelectric cooling at the end of a test and the fast and easy handling of the instrument save expensive labor time. The full color touch-screen of the MINIFLASH TOUCH runs on Microsoft® Windows® software and features an intuitive menu navigation that requires no training for flashpoint testing. Along with its convenient touch screen design, the MINIFLASH TOUCH offers an extended temperature range from 0 to 400°C, hassle-free communication with USB, Ethernet, LIMS and PCs and nearly unlimited storage capacity for programs and results. MINIFLASH determines the flash point according to ASTM D6450 and according to the advanced ASTM D7094 standard. This procedure describes the “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP)”, which offers the highest repeatability and reproducibility and an excellent correlation to the D93 Pensky-Martens method: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A” as concluded during the last Round Robin. Furthermore, test results are equivalent to other well known standards such as Abel and TAG, and thanks to its unique design MINIFLASH can be used for more difficult applications such as flash-point testing of contaminated samples like diesel fuel in lube oil or gasoline in diesel fuel and for biodiesel testing. The new MINIFLASH TOUCH analyzer also includes improved methods for simulation of EN ISO 3679 and EN ISO 3680. Due to true portability and rugged housing, the MINIFLASH TOUCH is also the perfect solution for mobile labs and military applications. Features Flashpoint according to ASTM D6450 (Flash-Point by Continuously Closed Cup) and ASTM D7094 (Flash-Point by Modified Continuously Closed Cup) FLASHPOINT COMMITTEE STATEMENT: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A.”), equivalent EN ISO 2719, excellent correlation to ASTM D56, ISO13736, IP170 New methods for EN ISO 3679 and EN ISO 3680 simulation Dilution Flashpoint Testing Go / No Go Flashpoint Testing Fast Screening Methods Automatic ignition cleaning method Maximum safety through Grabner continuously closed cup method (Ignition Protection Technology™) 1-2 ml sample size * No Open Flame, no offensive vapors in the lab * Highest accuracy (see precision statement) Extended temperature range: 0 to 400°C with external cooling (MINIFLASH FLPH TOUCH) Fully remote operable * Big, color touch-screen for convenient, intuitive menu navigation Touch Screen Runs on Microsoft® Windows®: Full integration with network, LIMS and PC Hassle-free communication and data transfer via USB and Ethernet USB printer support Good Laboratory Practice: User Access Control Portable for Mobile and Field Use (car battery connector) Worldwide standard method for the flavors and fragrances industry Approved for the ASTM specifications of recycled fuel and biodiesel Short measuring time (depends on sample type) due to small sample volume of 1-2 ml Combustion Analysis™ Excellent thermoelectric heating and cooling regulation through Peltier Protection Technology™ Specifications MINIFLASH FLP TOUCH: 0 to 200 C (32 to 390 F) MINIFLASH FLPH TOUCH: 0 to 400 C (32 to 750 F) MINIFLASH FLA/FLAH: With 8 sample capability autosampler Power Requirements: 100/110/230 V AC, 50/60 Hz, 150 W

Recommended Products For Biolab


Biolab TC40 Copper Corrosion Of Aromatic Hydrocarbons
Biolab TC16 Silver Corrosion System
Biolab Spectro LNF Q200 Series Particle Counter & Shape Classifier
Biolab TB 30 LPG Copper Corrosion
Biolab Aquamax KF Water Content Analyzer
Biolab MINIDIS ADXpert Automatic Mint-Distillation System
Biolab PETRA EDXRF Sulfur Analysis System
Biolab PETRODIST 200 Crude Oil Distillation System
Biolab DENSITY 4/5 Density Meter
Biolab Filmdist SP 200 Shorth Path Evaporator
Biolab Q6000 FDM Series Fuel Dilution Meter
Biolab M Series Signal Silicon Analyzer
Biolab Miniflash Touch Flash Point Analyzer
Biolab Filmdist TF 650 Thin-Film Evaporation
Biolab MiniLab 53 Oil Analysis System
Biolab SpectroT2FM Q500 Laboratory Ferrography
Biolab Polar Series Polarimeter
Biolab PAT940 TAN/TBN Analyzer
Gefran LS-A-N-0-Z-0900-0-000X-0-0-0X Linear Position Transducer
Eurotherm 2408/CC/VH/H7/XX/MS/FH/FE/XX/FRA/XXXXX/XXXXXX Controller Eurotherm 2408/CC/VH/H7/XX/MS/FH/FE/XX/FRA/XXXXX/XXXXXX Controller
Indexator 7212096 H 122 Rotator
Gefran LT-M-1100-P 0000X000A0N Potentiometer
Zeppelin M 300 Diverter Valve
Stahl 8570/11-511-S-01-0-00-XXX Wall Mounting Socket
Aron ADB3E01EW003 ADB3E Cetop 03 valve 4/2 DC Coil
Eaton Vickers (Danfoss) SV3 16 O 0 0 24DG Control Valve
Ebro-Armaturen Z 014-A Resilient Seated Valves
KSB MCPK150-125-250 GG NP2 A Pump
KSB UPFN 80/24+UMAH150-15/23-S.D Pump
Eaton Vickers (Danfoss) PCGV8CD 1 10 Valve
Mahle Pi 2130-068 77774516 Duplex Filter
Faulhaber 15A 546:1 Planetary Gearhead
Bottarini CC1053700 T25 VS Filter Element
Micro Detectors BX80A/4P-0H2D Area Sensor
SKF 623 Deep Groove Ball Bearings
Koso 710E Eccentric PARA-SEAL Valves
Amg Pesch SADF-45-60 Double-Piston Quarter Turn Actuator
Ham-let Tube Fitting H-400A Check Valve
Grundfos NK 100-225/235 AA1F1S3ESBQQEMW3 Pump
Italvibras MVSI 10/2100E-S08 6E2407 Increased Safety Electric Vibrator
Aignep 01VS SOLENOID PILOT VALVE
Edur CB(L)32-200/224-2900 Single Stage Close-Coupled Pump