im-tek.com

Biolab Miniflash Touch Flash Point Analyzer

Biolab

Product Code: Miniflash Touch
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab Miniflash Touch Flash Point Analyzer

MINIFLASH TOUCH is a uniquely designed flash point tester for the determination of flashpoints of liquids and solids, using the Grabner flash point detection method of measuring the instantaneous pressure increase inside the continuously closed chamber, triggered by an energy-controlled electric arc. Heating the test chamber from the top avoids condensation of high volatile compounds, significantly improving the test results. Its continuously closed cup design and small sample volume of only 1-2 mL offers maximum safety, avoids offensive fumes in the testing area and reduces sample waste. The fast thermoelectric cooling at the end of a test and the fast and easy handling of the instrument save expensive labor time. The full color touch-screen of the MINIFLASH TOUCH runs on Microsoft® Windows® software and features an intuitive menu navigation that requires no training for flashpoint testing. Along with its convenient touch screen design, the MINIFLASH TOUCH offers an extended temperature range from 0 to 400°C, hassle-free communication with USB, Ethernet, LIMS and PCs and nearly unlimited storage capacity for programs and results. MINIFLASH determines the flash point according to ASTM D6450 and according to the advanced ASTM D7094 standard. This procedure describes the “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP)”, which offers the highest repeatability and reproducibility and an excellent correlation to the D93 Pensky-Martens method: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A” as concluded during the last Round Robin. Furthermore, test results are equivalent to other well known standards such as Abel and TAG, and thanks to its unique design MINIFLASH can be used for more difficult applications such as flash-point testing of contaminated samples like diesel fuel in lube oil or gasoline in diesel fuel and for biodiesel testing. The new MINIFLASH TOUCH analyzer also includes improved methods for simulation of EN ISO 3679 and EN ISO 3680. Due to true portability and rugged housing, the MINIFLASH TOUCH is also the perfect solution for mobile labs and military applications. Features Flashpoint according to ASTM D6450 (Flash-Point by Continuously Closed Cup) and ASTM D7094 (Flash-Point by Modified Continuously Closed Cup) FLASHPOINT COMMITTEE STATEMENT: “There is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A.”), equivalent EN ISO 2719, excellent correlation to ASTM D56, ISO13736, IP170 New methods for EN ISO 3679 and EN ISO 3680 simulation Dilution Flashpoint Testing Go / No Go Flashpoint Testing Fast Screening Methods Automatic ignition cleaning method Maximum safety through Grabner continuously closed cup method (Ignition Protection Technology™) 1-2 ml sample size * No Open Flame, no offensive vapors in the lab * Highest accuracy (see precision statement) Extended temperature range: 0 to 400°C with external cooling (MINIFLASH FLPH TOUCH) Fully remote operable * Big, color touch-screen for convenient, intuitive menu navigation Touch Screen Runs on Microsoft® Windows®: Full integration with network, LIMS and PC Hassle-free communication and data transfer via USB and Ethernet USB printer support Good Laboratory Practice: User Access Control Portable for Mobile and Field Use (car battery connector) Worldwide standard method for the flavors and fragrances industry Approved for the ASTM specifications of recycled fuel and biodiesel Short measuring time (depends on sample type) due to small sample volume of 1-2 ml Combustion Analysis™ Excellent thermoelectric heating and cooling regulation through Peltier Protection Technology™ Specifications MINIFLASH FLP TOUCH: 0 to 200 C (32 to 390 F) MINIFLASH FLPH TOUCH: 0 to 400 C (32 to 750 F) MINIFLASH FLA/FLAH: With 8 sample capability autosampler Power Requirements: 100/110/230 V AC, 50/60 Hz, 150 W

Recommended Products For Biolab


Biolab Aquamax KF Water Content Analyzer
Biolab M Series Signal Silicon Analyzer
Biolab SpectroT2FM Q500 Laboratory Ferrography
Biolab TC40 Copper Corrosion Of Aromatic Hydrocarbons
Biolab PETRA EDXRF Sulfur Analysis System
Biolab TLC 15 Hydrometer Method Density Meter
Biolab Q6000 FDM Series Fuel Dilution Meter
Biolab Phoebe M Series Phosphorus Analyzer
Biolab MiniLab 53 Oil Analysis System
Biolab TC16 Copper Corrosion Analyzer
Biolab Clora M Series Chlorine Analyzer
Biolab PETRODIST 200 Crude Oil Distillation System
Biolab TLC Series Manuel Cloud And Pour Point Analyzer
Biolab SINDIE 7039 G3 Sulfur Analyzer
Biolab Parafuel Nir In-line Analyzer
Biolab PAT940 TAN/TBN Analyzer
Biolab MINIVAP VP Vision Vapor Pressure Tester
Biolab Spectroil Q100 Oil & Fuel Elemental Analysis Spectrometer
Ayvaz SC-200 Check Valve
Rhomberg AP430 Phase Sequence/Failure/Asymmetry Relay
Vulcanic 2006-14 Flange Immersion Heater
KSB ETN 065-040-250 CC CP1CGA2 B Pump
Winsmith 8CTT Triple Reduction Speed Reducer
Habasit TT122 Light Blue TPU Belt
Goyen K2003 (M1174B) Diaphragm Valve Repair Kit,
Senseca TV500L-100-0 Isolating Signal Converter
Gefran LM-L-A-0100 L000X030X Linear Position Transducer
Turian GR-15 1/2-7122 Rotary Joint
Gefran LT-F-0225-S 0000X000A00 Potentiometer
Stenflex Type SA-10 DN 150 Expansion Joint
Eaton 846AN00011A CVCS-16-D3-20 Valve Cover
Wilkerson F30-C8-F00
Alfa Laval TE67E131111140 PT: ´-1 to 0 bar 0,35% FS flange DN40,Cableoutlet,N/A
Micro Detectors C30P/BP-1E Proximity Sensor
Wandfluh BDRVDB4/40 Pressure Valve
Meister RMU-B02 Flow Monitor For Liquids
Knf FK 1.1100 KP .51 DCB-4 Diaphragm Liquid Pump
Gefran LT-M-1250-P 0000X000X0N Potentiometer
Stenflex Type SF-11 DN 200 Expansion Joint
Ringfeder RfN 7110 Locking Assembly
WARNER ELECTRIC CMS 250 Clutch/Brake
Emotron FDU48-1300-IP Drive