im-tek.com

Biolab SINDIE 7039 G3 Sulfur Analyzer

Biolab

Product Code: SINDIE 7039 G3
Brand: Biolab



GET OFFER: info@imtek.com.tr

Description for Biolab SINDIE 7039 G3 Sulfur Analyzer

The Sindie® 7039 Benchtop model is specifically designed for fast batch testing from 0.15 – 3000 ppm (wt.) sulfur fuel samples at petroleum pipeline terminals, refineries, and test laboratories. The unit is compact and fits on any lab bench with an easy-to-use and robust design for industrial and laboratory use with minimal maintenance. The Sindie ® analyzer has many advantages over competing technologies. The analyzer has exceptional signal-to-noise using monochromatic excitation of the X-ray source characteristic line. It does not require consumable gases or high-temperature operations improving the analyzer’s robustness and reliability. Sindie 7039 Benchtop complies with ASTM Standard D-7039. Sindie ® 7039 Benchtop meets or exceeds the performance of other X-ray fluorescence-based ISO and ASTM test methods including ISO 20884, for the measurement of sulfur in refinery fuels. The main features of the Sindie ® 7039 benchtop petroleum analyzer include: Direct measurement without sample conversion; Analysis in ppm (wt) LOD: 0.15 ppm Dynamic Range: 0.15 ppm to 3000 ppm Outstanding linearity: One calibration for diesel and gasoline matrices over full dynamic range Fast measurement time: 300 seconds No consumable gases required Extremely low maintenance Autosampler utilizes XOS Accu-Cell cup MWD XRF Monochromatic Wavelength Dispersive X-Ray Fluorescence (MWD XRF) utilizes state-of-the-art focusing and monochromating optics to increase excitation intensity and dramatically improve signal-to-background over high power traditional WD XRF instruments. This enables significantly improved detection limits and precision and a reduced sensitivity to matrix effects. A monochromatic and focused primary beam excites the sample and secondary characteristic fluorescence x-rays are emitted from the sample. A second monochromating optic selects the sulfur characteristic x-rays and directs these x-rays to the detector. MWD XRF is a direct measurement technique and does not require consumable gasses or sample conversion. Technical Data   LOD 0.15 ppm at 300 s Dynamic Range, Standard 0.15 ppm to 3000 ppm Dynamic Range, XR Package 0.15 ppm to 10% Test Methods ASTM D7039 and ISO 20884 Dimensions 37 cm (w) x 50 cm (d) x 34 cm (h)

Recommended Products For Biolab


Biolab Parafuel Nir In-line Analyzer
Biolab Filmdist SP 200 Shorth Path Evaporator
Biolab SINDIE 7039 G3 Sulfur Analyzer
Biolab PETRODIST 200 Crude Oil Distillation System
Biolab Q6000 FDM Series Fuel Dilution Meter
Biolab FluidScan® Q1100 Portable Oil Analysis System
Biolab Miniflash Touch Flash Point Analyzer
Biolab MINIDIS ADXpert Automatic Mint-Distillation System
Biolab Spectro LNF Q200 Series Particle Counter & Shape Classifier
Biolab MINISCAN IRXpert Gasoline Diesel And Jet Fuel Analyzer
Biolab TLC Series Manuel Cloud And Pour Point Analyzer
Biolab TC16 Copper Corrosion Analyzer
Biolab PORLA Stability Analyzer
Biolab Clora M Series Chlorine Analyzer
Biolab Aquamax KF Water Content Analyzer
Biolab Polar Series Polarimeter
Biolab HD Maxine XRF Elemental Analyzer
Biolab TC16 Silver Corrosion System
KWD ZAKU-N C 50000 Coupling
Aignep 51440 MALE - FEMALE BANJO STEM SINGLE
Greisinger OXY36100MP Atmospheric Oxygen Transducer
Vulcanic 2119-04 Screw Plug Immersion Heater
Gefran LT-H-0475-P L000X000B0N Potentiometer
Gefran LT-H-0300-S 0000X000X00 Potentiometer
Indexator 8000508 IR 20M M20 Rotator
Spirax Sarco M21Vi ISO Ball Valve
Roemheld B1.9470 Series Threaded-body Work Support
Wandfluh AM32061a Direct?onal Valve
VIMARC BDP 128-4 Vibrator motors
Habasit T04 Brown Rhomboid TPU Belt
Gefran LT-F-0350-S 0000X000A0N Potentiometer
Spirax Sarco BSA1T PN16 DN15 Metal Bellows Valve
Scherzinger 3040-110-ZK63-120 Hastelloy (R) Gear Pumps 3040
Inoxihp PF 150 Series Horizontal Triplex Plunger Pumps
Gefran LT-H-0100-P L000X000B00 Potentiometer
BUCHER QX61-250/53-040R Gear Pump
Faulhaber 22/7 112:1 Planetary Gearhead
Ru-Steel RP 110 RP 6 Bolt Range Without Spacer
Hengstler RI58-O/10000EK.46ID Encoder
Elcis 68 I02 - Series normal
KWD ELKU-N S2 100 - 355 x 30 - 50 H7P1 (x110) - 15 H7P1(x50) KWN 22013 Coupling
Edur NUB600D150L-3500 Single Stage Close-Coupled Pump