TECHNICAL DATA
Nominal size
25mm
Process connection
DN 25 PN 40 according to
DIN EN 1091
DN 50 PN 40 according to DIN EN 1091
(or Class 150/300 RF ANSI B16.5)
Material
stainless steel 1.4571 /
316 Ti
Density range
0 to 5000 kg/m³ (0 Ib/ft³
to 11023.11 Ib/ft³)
Calibration range
400 to 2000 kg/m³ (881.85
Ib/ft³ to 4409.25 Ib/ft³)
Accuracy
better than ±0.02%
(±0.2kg/m³ – ±0.044 Ib/ft³ )
Repeatability
besser als ±0.005%
(±0.05kg/m³ – ±0.11Ib/ft³)
Process temperature
-40°C to +150°C (-40°F to +
302°F)
Process pressure
40 bar (580.15 psi)
Output
With transmitter
electronics:
2-wire current output 4-20mA for operating density, reference density,
concentration, °Brix, °Plato or other quantities derived from density
As well as output of the medium temperature by PT100
With preamplifier:
Vibration frequency modulated to output current and output of the medium
temperature by PT100 in 4-wire technology for evaluation by an external flow
or density computer (e.g. series UR 06).
Ex-protection
Flame proof or
intrinsically safe
CHARACTERISTICS
·
direct measurement of density, reference
density or concentration
·
Quality monitoring of liquid media in
all industrial sectors
·
Indirect mass measurement in connection
with corresponding volume counters and flow computer
·
very robust construction
·
low installation costs
·
Measurement of almost all pumpable media
SPECIAL
FEATURES
·
high measuring accuracy
·
2-wire technology
·
Measurement independent of flow rate
·
Version without seals
·
material certificates