Product Name: CD Automation REVO E 3PH Thyristor power controller
Brand: CD Automation
Product Code: REVO E 3PH
Tags: CD Automation
CD power
Automation
CD REVO E 3PH power
CD Automation 3PH controller
Automation REVO Thyristor power
CD 3PH Thyristor power
CD Automation REVO E power controller
CD Automation REVO Thyristor power
Automation REVO E 3PH power
CD Automation REVO E power controller
CD REVO E Thyristor power controller
Automation E Thyristor power
CD 3PH
REVO power
CD Automation REVO E Thyristor controller
Automation REVO 3PH Thyristor
CD Automation power
CD Automation REVO 3PH Thyristor power
Automation REVO 3PH Thyristor power controller
CD REVO E 3PH Thyristor power
Thyristor power controller
Are you interested in the product CD Automation REVO E 3PH Thyristor power controller from manufacturer CD Automation with code REVO E 3PH? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!
Get Offer With E-Mail: info@im-tek.com
Get a offer for CD Automation REVO E 3PH Thyristor power controller from our live support team now!
REVO E 3PH Thyristor Power Controller is for Inductive Loads, including Resistance, Kanthal Super (MoSi2 Element) or SiC element on Secondary of Transformer, an Universal and Digital Unit based on configurable powerfull microprocessor. It is possible to configure all inputs, the firing mode and control mode for all load type.SCR Power Controller suitable for most applications including Short Wave Infrared (SWIR) & Inductive load typesCurrent range – 35A, 45A, 75A, 100A, 125A, 150A, 225, 300A, 350A, 400A, 450A, 500AThree leg switching of 3/4 wire star or 3/6 wire delta loadsFully digital and user configurable for all inputs, firing modes, feedback modes and load typesFiring modes include zero crossing (ZC), burst firing (BF), single cycle (SC), soft start + burst firing (S+BF) and phase angle + soft start (S+PA)Microprocessor based electronic circuit fully isolated from powerUniversal input signal with automatic zero/span calibrationPower feedback or voltage compensationRS485 Comms MODBUS protocol as standardUnbalanced loadHeater break alarm to diagnose partial or total load failure and short circuitControl & monitor power, current & voltage via external keypad (CD-KP)IP20 ProtectionFrom 35 up to 500AMax. voltage 480V or 600V AC as optionDesigned to drive resistive, transformer loads and MoSi2 ElementsInputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.Firing mode: zero crossing, burst firing, single cycle, soft start + burst firing and phase angle + soft startN°1 Retransmission is available