Cemb T7-LVDT Valves Position Transducer


Cemb T7-LVDT  Valves Position Transducer Image

Are you interested in the product Cemb T7-LVDT Valves Position Transducer from manufacturer Cemb with code T7-LVDT? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!

Get Offer With E-Mail: info@im-tek.com
Get a offer for Cemb T7-LVDT Valves Position Transducer from our live support team now!

Transducer T7-LVDT is used for measuring, through the position transducer system with linear variable differential transformer (LVDT), the OPENING POSITION of steam VALVES in a turbine; the measurement is performed by keying the transducer shaft integrally with the valve opening control device in order to measure the rotation of such device. The signal picked up should be sent to a measuring channel CEMB /T7 units for processing.Range of measurement0 to 120°Sensitivity5 mV/°Transformer LVDTRange = ±5.08 mmImpedance, primary winding = 970 ohm/2500 HzImpedance, secondary windings = 1010 ohm/2500 HzMax linearity error = ± 0.5% f.s.Nominal sensitivity = 63 mV/mmFrequency range = 50 Hz to 10 kHzSupply voltage = 3 V rms (rated)Range of applicationTemperature = -55°C to +95°CHumidity = max 95% not condensingVibrations = max 20 g / 2 KHzAmbient = IP55 EN60529/10.90 standardsPower supply± 15 Vdc, GNDConnectionconnector 7-pin MIL C-5015 series 3106/16, standard kitOuter casing materialAluminiumWeightKg 3 approx.Maintenancenone