德国仓直发,全球快速配送
多种支付方式多种付款选项
VisaMastercardAmerican ExpressDiners ClubDiscover
  1. 产品
  2. Greyline
  3. 仪表
  4. Greyline ISM 5.0 Insertion Magmeter

Greyline ISM 5.0 Insertion Magmeter

Technical Documentation

技术数据表 / 产品文档

  • 目前暂无此产品的技术文档。如需更多信息,请与我们联系。
WhatsApp
品牌
类别仪表
产品名称Greyline ISM 5.0 Insertion Magmeter
产品编号ISM 5.0
Visa – Secure credit card payment acceptedMastercard – Secure credit card payment acceptedAmerican Express – Secure credit card payment acceptedDiners Club – Secure credit card payment acceptedDiscover – Secure credit card payment accepted

欢迎联系我们!我们会在 24 个工作小时内(不含周末及节假日)确认库存状态和预计交期。

产品描述

Greyline的产品(包括Greyline ISM 5.0 Insertion Magmeter)通过平行进口渠道采购,并快速可靠地交付给United States的客户。Imtek Engineering以具有竞争力的价格提供正品Greyline零部件。即使Greyline ISM 5.0 Insertion Magmeter未在我们的网站上列出,您也可以随时申请报价——我们的团队将迅速响应并为您提供专属报价。

Insertion Magmeter
  • electromagnetic with no moving parts
  • simplified hot tap insertion design
  • installs in 3-72" (80-1800 mm) diameter pipes
  • selectable 4-20mA, 0-5V or 0-10V output
  • 0-500Hz frequency output
  • scalable pulse output

Accurate, Low Cost Alternative to Full-bore Magnetic Flow Meters

Measure flow of water and conductive liquids in full pipes from 3 to 72" (80 to 1800 mm) diameter.

The ISM 5.0 dual pair electrode sensor inserts through a tap in the pipe wall. It can be easily installed in new pipe systems or by hot tap in pressurized pipes with flowing liquids. There are no moving parts so obstruction to flow and pressure drop is minimal. Installation through a full port ball valve allows easy retraction and reinsertion without shutting down flow. The insertion depth is adjustable according to the pipe diameter and an insertion depth gauge is supplied with each flowmeter. The optional Installation Hardware Kit includes a branch outlet, close nipple and full port 1” isolation valve. 

The ISM 5.0 Insertion Magmeter senses flow using a low maintenance electromagnetic design with no moving parts. The dual-electrode sensor and continuous auto-zero function provides high accuracy – even at low flow rates. State-of-the-art electronics and patented design features help maintain its NIST traceable accuracy over time.

No Onsite Calibration Required

Based on your pipe type and size, liquid and flow rate each ISM 5.0 Insertion Magmeter is shipped from our factory configured for your application and ready to install. Connect the isolated 4-20mA output to control system or remote display, or use the relay pulse output.


Installs through a Ball Valve into the pipe

How It Works

The ISM 5.0 Insertion Magmeter operates based on Faraday’s Law of electromagnetic induction: as flow velocity of a liquid increases through the magnetic field generated by the sensor head of the ISM flow meter, electrodes measure the voltage increase to accurately calculate flow. Four electrodes measure the induced voltage on opposite sides of the sensor. The voltage readings are sampled and averaged.

The ISM 5.0 Insertion Magmeter measures flow of electrically conductive liquids (20 µS/cm or greater) in full pipes. For proper measurement on plastic pipes the electromagnetic flow meter requires electrical grounding by connection to grounding rings or ground probes inserted into the pipe. Readings are not affected by the fluid temperature, pressure or viscosity.



INSERTION MAGMETER SPECIFICATIONS

Provide a Greyline ISM 5.0 Insertion Magmeter complete with all installation hardware necessary to enable insertion and removal of the meter without system shutdown. The flow meter shall be hand-insertable up to 400 psi. For installations in non-metallic pipe, install grounding rings or probes. Materials of construction for wetted metal components shall be 316 SS.  The flow meter shall average velocity readings from two sets of diametrically opposed electrodes.  Each flow meter shall be individually wet-calibrated against a primary volumetric standard that is accurate to within 0.1% and traceable to NIST*.  A certificate of calibration shall be provided with each flow meter. Accuracy shall be within ± 1% of rate from 2-20 ft/s. Overall turndown shall exceed 100:1.

Output signals shall be completely isolated and shall consist of the following: (1) analog output; 4-20mA, 0-10V, or 0-5V jumper selectable, (1) scalable dry contact output for totalization, and (1) high resolution frequency output for use with peripheral devices.  ISM 5.0-B for Bi-directional applications shall provide additional contact outputs for direction and flow totalization in each direction. Each flow meter shall be certified to NSF Standards and covered by the manufacturer’s two-year warranty.

* National Institute of Standards and Technology

Optional Flow Display

D-100 Series Display Module for network interface and local / remote indication of flow rate and total.

常见问题

关于Greyline品牌Greyline ISM 5.0 Insertion Magmeter产品的常见问题。Imtek Engineering随时准备帮助您在United States采购GreylineGreyline ISM 5.0 Insertion Magmeter

Imtek Engineering通过可信赖的供应渠道采购正品Greyline产品,并以具有竞争力的价格向United States客户提供。