BECKHOFF KS9400 Power supply unit terminal for the K-bus
Product Code:KS9400
Description
The KL9400 power supply unit terminal is used to refresh the K-bus. Data is exchanged between the Bus Coupler and Bus Terminal over the K-bus. Each Bus Terminal draws a certain amount of current from the K-bus (see “Current consumption K-bus” in the technical data). This current is fed into the K-bus by the relevant Bus Coupler’s power supply unit. The standard couplers (BKxx00, BCxx00) make 1.75 A available to the K-bus. In configurations with a large number of Bus Terminals it is possible to use the KL9400 in order to supply an extra 2 A to the K-bus.
Technical dataKL9400 | KS9400Input voltage24 V DC (-15 %/+20 %)Output voltage5 V DCOutput current2 A for K-bus supplyDiagnostics–Current consumption K-bus–Power contactsmax. 24 V DC/max. 10 AShort-circuit proofyesElectrical isolation–Residual ripple–Weightapprox. 65 gOperating/storage temperature-25…+60 °C/-40…+85 °CRelative humidity95 %, no condensationVibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4Protect. class/installation pos.IP 20/variablePluggable wiringfor all KSxxxx Bus TerminalsApprovals/markingsCE, UL, ATEX, GLEx markingII 3 G Ex nA IIC T4 GcTechnical Specifications
KL9400 | Power supply unit terminal for the K-bus
The KL9400 power supply unit terminal is used to refresh the K-bus. Data is exchanged between the Bus Coupler and Bus Terminal over the K-bus. Each Bus Terminal draws a certain amount of current from the K-bus (see “Current consumption K-bus” in the technical data). This current is fed into the K-bus by the relevant Bus Coupler’s power supply unit. The standard couplers (BKxx00, BCxx00) make 1.75 A available to the K-bus. In configurations with a large number of Bus Terminals it is possible to use the KL9400 in order to supply an extra 2 A to the K-bus.
| Technical data | KL9400 | KS9400 |
|---|---|
| Input voltage | 24 V DC (-15 %/+20 %) |
| Output voltage | 5 V DC |
| Output current | 2 A for K-bus supply |
| Diagnostics | – |
| Current consumption K-bus | – |
| Power contacts | max. 24 V DC/max. 10 A |
| Short-circuit proof | yes |
| Electrical isolation | – |
| Residual ripple | – |
| Weight | approx. 65 g |
| Operating/storage temperature | -25…+60 °C/-40…+85 °C |
| Relative humidity | 95 %, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 20/variable |
| Pluggable wiring | for all KSxxxx Bus Terminals |
| Approvals/markings | CE, UL, ATEX, GL |