BUCHER MTDA08-012M Flow Divider
Product Code:MTDA08-012M
Description
Series MTDA units are flow dividing valves that operate automatically. They are intended for use with hydraulic fluids. They divide a flow, the total rate of which may be varied, up to 4 part-flows. When flow passes through a valve in the opposite direction, the part-flows are combined into one single flow (added).
The dividing and combining functions are largely independent of the pressures of the divided flows and of the fluid viscosity.
AdvantagesThese valves do not require maintenance. This lowers costs and reduces the risk of a system failure. Flows can be split or merged with accuracy (divide/combine functions).The flow division ratio can be altered to suit customer requirements. Options:- end-of-stroke equalisation
- make-up valves
- check valves
- pressure-relief valvesTechnical DataTypeNominal size
Max. operating pressure
- Standard
barMax. operating pressure
- High pressure version
barVolume flow rate
l/minDiv. accuracy
%Division ratio
MTDA088315-2 - 100+/- 31:1*MTDA083F8315-2 - 100+/- 31:1*MTDA08HD8-4202 - 100+/- 31:1*MTDA16HD16-42025 - 250+/- 31:1*MTDA08HG8250-5 - 50+/- 1,51:1*MTDA084F8315-2 - 100+/- 31:1*MTDA1616315-35 - 250+/- 31:1*
* unequal partition by cusomer´s wish
213.5 KBModelsStandardMTDA083FMTDA084FHigh Pressure VersionApplicationsWork access platforms Lifting platformHarvesters Municipal equipment Snow/ice clearing equipment Wood chippers Raod rollersTail lifts
Technical Specifications
Flow Divider MTDA

Description
Series MTDA units are flow dividing valves that operate automatically. They are intended for use with hydraulic fluids. They divide a flow, the total rate of which may be varied, up to 4 part-flows. When flow passes through a valve in the opposite direction, the part-flows are combined into one single flow (added).
The dividing and combining functions are largely independent of the pressures of the divided flows and of the fluid viscosity.
Advantages
- These valves do not require maintenance. This lowers costs and reduces the risk of a system failure.
- Flows can be split or merged with accuracy (divide/combine functions).
- The flow division ratio can be altered to suit customer requirements.
- Options:
- end-of-stroke equalisation
- make-up valves
- check valves
- pressure-relief valves
Technical Data
| Type | Nominal size | Max. operating pressure - Standard bar | Max. operating pressure - High pressure version bar | Volume flow rate l/min | Div. accuracy % | Division ratio |
|---|---|---|---|---|---|---|
| MTDA08 | 8 | 315 | - | 2 - 100 | +/- 3 | 1:1* |
| MTDA083F | 8 | 315 | - | 2 - 100 | +/- 3 | 1:1* |
| MTDA08HD | 8 | - | 420 | 2 - 100 | +/- 3 | 1:1* |
| MTDA16HD | 16 | - | 420 | 25 - 250 | +/- 3 | 1:1* |
| MTDA08HG | 8 | 250 | - | 5 - 50 | +/- 1,5 | 1:1* |
| MTDA084F | 8 | 315 | - | 2 - 100 | +/- 3 | 1:1* |
| MTDA16 | 16 | 315 | - | 35 - 250 | +/- 3 | 1:1* |
* unequal partition by cusomer´s wish
Models
Standard

MTDA083F

MTDA084F

High Pressure Version

Applications
- Work access platforms
- Lifting platform
- Harvesters
- Municipal equipment
- Snow/ice clearing equipment
- Wood chippers
- Raod rollers
- Tail lifts