Schnelle Lieferung von DEUTSCHLAND in die ganze Welt
Vielfältige ZahlungsoptionenMehrere Zahlungsmethoden
VisaMastercardAmerican ExpressDiners ClubDiscover
  1. Produkte
  2. Fife
  3. Sensor
  4. Fife SE-46C Line Sensor

Fife SE-46C Line Sensor

Technical Documentation

Technische Datenblätter / Produktdokumentation

WhatsApp
Marke
KategorieSensor
ProduktnameFife SE-46C Line Sensor
ProduktcodeSE-46C
Visa – Secure credit card payment acceptedMastercard – Secure credit card payment acceptedAmerican Express – Secure credit card payment acceptedDiners Club – Secure credit card payment acceptedDiscover – Secure credit card payment accepted

Kontaktieren Sie uns! Innerhalb von 24 Geschäfts­stunden (ohne Wochenenden und Feiertage) bestätigen wir Lagerstatus und voraussichtliche Lieferzeit.

Produktbeschreibung

Fife-Produkte, einschließlich Fife SE-46C Line Sensor, werden über Parallelimportkanäle bezogen und zuverlässig an unsere Kunden in United States geliefert. Imtek Engineering bietet Original-Fife-Teile zu wettbewerbsfähigen Preisen an. Auch wenn Fife SE-46C Line Sensor nicht auf unserer Website gelistet ist, können Sie jederzeit ein Preisangebot anfordern – unser Team meldet sich umgehend.

2-5
COMMISSIONING OF D-MAX
2.1. Setting ASC thresholds
D-MAX OI-N operator interface:
∙ Select menu 1y.3.y6.2 (Job Settings ASC ASC Threshold 1 (Pos)) ∙ Set ASC threshold 1 (pos) to 90.0%
∙ Select menu 1y.3.y6.3 (Job Settings ASC ASC Threshold 2 (Neg)) ∙ Set ASC threshold 2 (neg) to −90.0%
2.2. Switching on the ASC function
D-MAX OI-N operator interface:
∙ Select menu 1y.3.y6.1 (Job Settings ASC ASC State) ∙ Set the ASC State to ON
3. Setting the polarity and gain
3.1. Setting the polarity
Note:
Connection to X5: job with y = 'J' Connection to X9: job with y = 'K
The guiding direction (polarity) must be checked depending on the mechanical installation direction of the system and adjusted
if necessary.
D-MAX OI-N operator interface:
∙ Select menu1.y.3.y8 (Job Settings Polarity) ∙ Set the polarity
3.2. Setting the gain
The gain must be set optimally.
D-MAX OI-N operator interface:
∙ Select menu 1.y.3.y3 (Job Settings Gain) ∙ Set the gain
MI 1071 1
SE-46C Commissioning of the web guide controllers
www.maxcess.eu

Häufige Fragen

Häufig gestellte Fragen zu Fife SE-46C Line Sensor von Fife. Imtek Engineering hilft Ihnen gerne, Fife SE-46C Line Sensor von Fife in United States zu beschaffen.

Imtek Engineering bezieht originale Fife Produkte über vertrauenswürdige Lieferkanäle und stellt sie Kunden in United States zu wettbewerbsfähigen Preisen zur Verfügung.