Industrielle Ersatzteile & Engineering-Lösungen seit 2001.
Gestra CW44 Cooling-Water Control Valve
Technische Datenblätter / Produktdokumentation
| Marke | ![]() |
| Kategorie | Ventil |
| Produktname | Gestra CW44 Cooling-Water Control Valve |
| Produktcode | Nicht angegeben |
Kontaktieren Sie uns! Innerhalb von 24 Geschäftsstunden (ohne Wochenenden und Feiertage) bestätigen wir Lagerstatus und voraussichtliche Lieferzeit.
Produktbeschreibung
Gestra-Produkte, einschließlich Gestra CW44 Cooling-Water Control Valve, werden über Parallelimportkanäle bezogen und zuverlässig an unsere Kunden in United States geliefert. Imtek Engineering bietet Original-Gestra-Teile zu wettbewerbsfähigen Preisen an. Auch wenn Gestra CW44 Cooling-Water Control Valve nicht auf unserer Website gelistet ist, können Sie jederzeit ein Preisangebot anfordern – unser Team meldet sich umgehend.
Technical data Dimensions and weights ~190 mm
◗ CW 44, CW 44k Weights Nominal size
G 3/8
G 1/2
G 3/4
G1
Weight [kg]
3.2
3.1
3.1
3.0
Temperature & pressure ratings Pressure
p [barg]
25
Temperature
T [°C]
120 (CW 44) 85 (CW 44k)
Maximum differential pressure
∆PMX [bar]
16
Adjustable outlet temperature
[°C]
n-thermostat: -2/106 (CW 44) k-thermostat: -37/71 (CW 44k)
Troubleshooting Problem
Cause
Action
The flow rate is too low.
The size and design of the The planned return temperature is equipment differ from the
not reached.
system data.
Change the equipment settings.
Check the size.
Use equipment of a size that conforms to the system data.
Fluid is escaping (leakage).
The equipment or body is damaged.
Replace the equipment.
Fluid is escaping (leakage).
A gasket is damaged.
Replace the damaged gasket.
Clean the sealing surfaces.
The equipment does not regulate The control unit is damaged the flow perfectly.
or worn.
Replace the equipment.
The equipment is working irreg- The pipe between the heat Increase the bleed flow.
ularly. Inner parts open and close exchanger and the equipment Install the equipment immediately
at intervals.
is too long.
downstream of the heat exchanger.
The flow rate is too high. The The equipment is incorrectly planned return temperature is set.
not reached.
The movement of inner parts is obstructed by deposits.
Check the equipment settings.
Reduce the bleed flow.
Check the equipment settings.
Reduce the bleed flow.
Clean the equipment.
Make sure that the movement of inner parts is not obstructed.
11
Häufige Fragen
Häufig gestellte Fragen zu Gestra CW44 Cooling-Water Control Valve von Gestra. Imtek Engineering hilft Ihnen gerne, Gestra CW44 Cooling-Water Control Valve von Gestra in United States zu beschaffen.
Imtek Engineering bezieht originale Gestra Produkte über vertrauenswürdige Lieferkanäle und stellt sie Kunden in United States zu wettbewerbsfähigen Preisen zur Verfügung.



