HEIDENHAIN LS 177 Sealed Linear Encoder
Product Code:LS 177
Description
Specifications
LS 187
LS 177
Measuring standard
Coefficient of linear expansion
Glass scale with DIADUR grating, grating period 20 µm
?therm 8 x 10–6 K–1
Accuracy grade*
±5 µm; ±3 µm
Measuring length ML* in mm
140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440
1540 1640 1740 1840 2040 2240 2440 2640 2840 3040
Reference marks* LS 1x7
LS 1x7 C
Selectable with magnets every 50 mm, standard setting: 1 reference mark in the center
Distance-coded
Interface
1 VPP
? TTL
Integrated interpolation*
Signal period
–
20 µm
5-fold
–
10-fold
–
20-fold
–
Diagnostics interface
Analog
–
Cutoff frequency –3 dB
? 160 kHz
–
–
–
Scanning frequency*
Edge separation a
–
100 kHz
? 0.5 µs
50 kHz
? 1 µs
100 kHz
? 0.25 µs
50 kHz
? 0.5 µs
25 kHz
? 1 µs
50 kHz
? 0.25 µs
25 kHz
? 0.5 µs
Measuring step
Depends on interpolation
1 µm1)
0.5 µm1)
0.25 µm1)
Electrical connection
Separate adapter cable (1 m/3 m/6 m/9 m) connectible to mounting block
Cable length2)
? 150 m
? 100 m
Voltage supply
without load
DC 5 V ±0.25 V/< 120 mA
DC 5 V ±0.25 V/< 140 mA
Traversing speed
? 120 m/min
? 120 m/min
? 60 m/min
? 120 m/min
? 60 m/min
? 30 m/min
? 60 m/min
? 30 m/min
Required moving force
? 4 N
Vibration 55 Hz to 2000 Hz
Shock 11 ms
Acceleration
? 200 m/s2 (EN 60 068-2-6)
? 400 m/s2 (EN 60 068-2-27)
? 60 m/s2 in measuring direction
Operating temperature
0 °C to 50 °C
Protection EN 60 529
IP53 when mounted according to the instructions and mounting information
IP64 if compressed air is connected via DA 400
Mass
0.4 kg + 2.3 kg/m measuring length
* Please select when ordering
1) After 4-fold evaluation in the subsequent electronics
2) With HEIDENHAIN cable
Technical Specifications
Specifications | LS 187 | LS 177 | ||||||
Measuring standard Coefficient of linear expansion | Glass scale with DIADUR grating, grating period 20 µm ?therm 8 x 10–6 K–1 | |||||||
Accuracy grade* | ±5 µm; ±3 µm | |||||||
Measuring length ML* in mm | 140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 2040 2240 2440 2640 2840 3040 | |||||||
Reference marks* LS 1x7 LS 1x7 C | Selectable with magnets every 50 mm, standard setting: 1 reference mark in the center Distance-coded | |||||||
Interface | 1 VPP | ? TTL | ||||||
Integrated interpolation* Signal period | – 20 µm | 5-fold – | 10-fold – | 20-fold – | ||||
Diagnostics interface | Analog | – | ||||||
Cutoff frequency –3 dB | ? 160 kHz | – | – | – | ||||
Scanning frequency* Edge separation a | – | 100 kHz ? 0.5 µs | 50 kHz ? 1 µs | 100 kHz ? 0.25 µs | 50 kHz ? 0.5 µs | 25 kHz ? 1 µs | 50 kHz ? 0.25 µs | 25 kHz ? 0.5 µs |
Measuring step | Depends on interpolation | 1 µm1) | 0.5 µm1) | 0.25 µm1) | ||||
Electrical connection | Separate adapter cable (1 m/3 m/6 m/9 m) connectible to mounting block | |||||||
Cable length2) | ? 150 m | ? 100 m | ||||||
Voltage supply | DC 5 V ±0.25 V/< 120 mA | DC 5 V ±0.25 V/< 140 mA | ||||||
Traversing speed | ? 120 m/min | ? 120 m/min | ? 60 m/min | ? 120 m/min | ? 60 m/min | ? 30 m/min | ? 60 m/min | ? 30 m/min |
Required moving force | ? 4 N | |||||||
Vibration 55 Hz to 2000 Hz Shock 11 ms Acceleration | ? 200 m/s2 (EN 60 068-2-6) ? 400 m/s2 (EN 60 068-2-27) ? 60 m/s2 in measuring direction | |||||||
Operating temperature | 0 °C to 50 °C | |||||||
Protection EN 60 529 | IP53 when mounted according to the instructions and mounting information IP64 if compressed air is connected via DA 400 | |||||||
Mass | 0.4 kg + 2.3 kg/m measuring length | |||||||
* Please select when ordering 1) After 4-fold evaluation in the subsequent electronics 2) With HEIDENHAIN cable | ||||||||