IMTEK Engineering

Hirschmann

Hirschmann 5Tx 943824-002 Railswitch Spider

Product Code:5Tx 943824-002 Railswitch Spider

Description

More InterfacesPower supply/signaling contact1 plug-in terminal block, 3-pin, no signal contactNetwork size - Length of cableTwisted pair (TP)0 - 100 mNetwork size - CascadibilityLine - / star topologyanyPower requirementsOperating voltage9.6 VDC - 32 VDCCurrent consumption at 24 V DCmax. 100 mAPower consumptionmax. 2.2 W; 7.5 Btu(IT)/h at 24 VDCServiceDiagnosticsLEDs (power, link status, data, data rate)Ambient conditionsOperating temperature0 C to +60 CStorage/transport temperature-40 C to +70 CRelative humidity (non-condensing)10% to 95%MTBF123.7 years, MIL-HDBK 217F: Gb 25 CMechanical constructionDimensions (W x H x D)25 mm x 114mm x 79 mmMountingDIN Rail 35 mmWeight113 gProtection classIP 30Mechanical stabilityIEC 60068-2-27 shock15 g, 11 ms duration, 18 shocksIEC 60068-2-6 vibration3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.EMC interference immunityEN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air dischargeEN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data lineEN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data lineEN 61000-4-6 conducted immunity10 V (150 kHz - 80 kHz)EMC emitted immunityFCC CFR47 Part 15FCC CFR47 Part 15 Class AEN 55022EN 55022 Class AApprovalsSafety of industrial control equipmentcUL 508Scope of delivery and accessoriesScope of deliverydevice, terminal block, operating manualAccessories to order separatelyRail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame

Technical Specifications

More Interfaces
Power supply/signaling contact1 plug-in terminal block, 3-pin, no signal contact
Network size - Length of cable
Twisted pair (TP)0 - 100 m
Network size - Cascadibility
Line - / star topologyany
Power requirements
Operating voltage9.6 VDC - 32 VDC
Current consumption at 24 V DCmax. 100 mA
Power consumptionmax. 2.2 W; 7.5 Btu(IT)/h at 24 VDC
Service
DiagnosticsLEDs (power, link status, data, data rate)
Ambient conditions
Operating temperature0 C to +60 C
Storage/transport temperature-40 C to +70 C
Relative humidity (non-condensing)10% to 95%
MTBF123.7 years, MIL-HDBK 217F: Gb 25 C
Mechanical construction
Dimensions (W x H x D)25 mm x 114mm x 79 mm
MountingDIN Rail 35 mm
Weight113 g
Protection classIP 30
Mechanical stability
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity10 V (150 kHz - 80 kHz)
EMC emitted immunity
FCC CFR47 Part 15FCC CFR47 Part 15 Class A
EN 55022EN 55022 Class A
Approvals
Safety of industrial control equipmentcUL 508
Scope of delivery and accessories
Scope of deliverydevice, terminal block, operating manual
Accessories to order separatelyRail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame