IMTEK Engineering

Hirschmann

Hirschmann 942120-001 Spider I? 16Tx Eec

Product Code:942120-001 Spider I? 16Tx Eec

Description

More InterfacesPower supply/signaling contact1 plug-in terminal block, 5-pin / no signaling contactNetwork size - Length of cableTwisted pair (TP)0 - 100 mNetwork size - CascadibilityLine - / star topologyanyPower requirementsOperating voltage18 VDC - 32 VDC redundantCurrent consumption at 24 V DC0.41 APower consumption9.8 WServiceDiagnosticsLEDs (power, link status, data, data rate)Ambient conditionsOperating temperature-40 C to +70 CStorage/transport temperature-45 C to +85 CRelative humidity (non-condensing)5% to 95%MTBF326,298 h (Telcordia)Mechanical constructionDimensions (W x H x D)66 mm x 138 mm x 111 mmMountingDIN Rail 138 mmWeight730 gProtection classIP 30Mechanical stabilityIEC 60068-2-27 shock15 g, 11 ms duration, 18 shocksIEC 60068-2-6 vibration3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.EMC interference immunityEN 61000-4-2 electrostatic discharge (ESD)4 kV contact discharge, 8 kV air dischargeEN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data lineEN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 2 kV data lineEN 61000-4-6 conducted immunity10 V (150 kHz - 80 kHz)EMC emitted immunityFCC CFR47 Part 15FCC CFR47 Part 15 Class AEN 55022EN 55022 Class AApprovalsSafety of industrial control equipmentcUL 60950-1, cUL 508Hazardous LocationsISA 12.12.01 Class 1 Div. 2 (pending); ATEX, Zone 2 (pending)Scope of delivery and accessoriesScope of deliverydevice, terminal block, operating manualAccessories to order separatelyRail Power Supply RPS 30, RPS 80 EEC or RPS 120 EEC

Technical Specifications

More Interfaces
Power supply/signaling contact1 plug-in terminal block, 5-pin / no signaling contact
Network size - Length of cable
Twisted pair (TP)0 - 100 m
Network size - Cascadibility
Line - / star topologyany
Power requirements
Operating voltage18 VDC - 32 VDC redundant
Current consumption at 24 V DC0.41 A
Power consumption9.8 W
Service
DiagnosticsLEDs (power, link status, data, data rate)
Ambient conditions
Operating temperature-40 C to +70 C
Storage/transport temperature-45 C to +85 C
Relative humidity (non-condensing)5% to 95%
MTBF326,298 h (Telcordia)
Mechanical construction
Dimensions (W x H x D)66 mm x 138 mm x 111 mm
MountingDIN Rail 138 mm
Weight730 g
Protection classIP 30
Mechanical stability
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 2 kV data line
EN 61000-4-6 conducted immunity10 V (150 kHz - 80 kHz)
EMC emitted immunity
FCC CFR47 Part 15FCC CFR47 Part 15 Class A
EN 55022EN 55022 Class A
Approvals
Safety of industrial control equipmentcUL 60950-1, cUL 508
Hazardous LocationsISA 12.12.01 Class 1 Div. 2 (pending); ATEX, Zone 2 (pending)
Scope of delivery and accessories
Scope of deliverydevice, terminal block, operating manual
Accessories to order separatelyRail Power Supply RPS 30, RPS 80 EEC or RPS 120 EEC

Request a Quote

Contact us for pricing and availability

Email Us Contact Form