Imtek Engineering

Hirschmann

Hirschmann RS2-3TX/2FX EEC 943771-001 Rail Switch

Product Code:RS2-3TX/2FX EEC 943771-001 Rail Switch

Description

Power supply/signaling contact1 plug-in terminal block, 5-pinNetwork size - Length of cableTwisted pair (TP)0 - 100 mMultimode fiber (MM) 50/125 µm0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x kmMultimode fiber (MM) 62.5/125 µm0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x kmNetwork size - CascadibilityLine - / star topologyanyPower requirementsOperating voltage24 V DC (-25% to +30%)Current consumption at 24 V DCmax. 230 mAPower consumptionmax. 5.9 W at 24 V DCServiceDiagnosticsLEDs (power, link status, data, error), signal contact / fault relays (24 VDC / 1A)RedundancyRedundancy functionsredundant 24 V power supplyAmbient conditionsOperating temperature-40 C to +70 CStorage/transport temperature-40 C to +85 CRelative humidity (non-condensing)10% to 95%MTBF43.4 years; MIL-HDBK 217F: Gb 25 CMechanical constructionDimensions (W x H x D)47 mm x 135 mm x 111 mmMountingDIN Rail 35 mmWeight320 gProtection classIP 20Mechanical stabilityIEC 60068-2-27 shock15 g, 11 ms duration, 18 shocksIEC 60068-2-6 vibration1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.EMC interference immunityEN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air dischargeEN 61000-4-3 electromagnetic field10 V/m (80-1000 MHz)EN 61000-4-4 fast transients (burst)2 kV power line, 1 kV data lineEN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data lineEN 61000-4-6 conducted immunity3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)EMC emitted immunityFCC CFR47 Part 15FCC CFR47 Part 15 Class AEN 55022EN 55022 Class AApprovalsSafety of industrial control equipmentcUL 508Hazardous locationsISA 12.12.01 Class 1 Div. 2ShipbuildingGermanischer LloydScope of delivery and accessoriesScope of deliverydevice, terminal block, operating manualAccessories to order separatelyrail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame

Technical Specifications

Power supply/signaling contact1 plug-in terminal block, 5-pin
Network size - Length of cable
Twisted pair (TP)0 - 100 m
Multimode fiber (MM) 50/125 µm0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Network size - Cascadibility
Line - / star topologyany
Power requirements
Operating voltage24 V DC (-25% to +30%)
Current consumption at 24 V DCmax. 230 mA
Power consumptionmax. 5.9 W at 24 V DC
Service
DiagnosticsLEDs (power, link status, data, error), signal contact / fault relays (24 VDC / 1A)
Redundancy
Redundancy functionsredundant 24 V power supply
Ambient conditions
Operating temperature-40 C to +70 C
Storage/transport temperature-40 C to +85 C
Relative humidity (non-condensing)10% to 95%
MTBF43.4 years; MIL-HDBK 217F: Gb 25 C
Mechanical construction
Dimensions (W x H x D)47 mm x 135 mm x 111 mm
MountingDIN Rail 35 mm
Weight320 g
Protection classIP 20
Mechanical stability
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80-1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 1 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15FCC CFR47 Part 15 Class A
EN 55022EN 55022 Class A
Approvals
Safety of industrial control equipmentcUL 508
Hazardous locationsISA 12.12.01 Class 1 Div. 2
ShipbuildingGermanischer Lloyd
Scope of delivery and accessories
Scope of deliverydevice, terminal block, operating manual
Accessories to order separatelyrail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame

Request a Quote

Contact us for pricing and availability

Email Us Contact Form