4740/41 Series Filter Assemblies
Formun Üstü
Coralon® lube and hydraulic oil filters deliver consistent, high level fluid system protection across all applications, regardless of severity. Coralon filters feature BetaX(C) >1000 filter efficiency, low pressure drop and long service life.
Formun Altı
Features Flows to 340 lpm (90 US gpm) Pressures to 450 bar (6500 psi) Port size: 1½” Notes and SpecificationsFilter Housing Fatigue Pressure Rating
400 bar (5800 psi) per NFPA T2.6.1 R2-2001 Cat C/90
Typical Burst Pressure:1,600 bar (23,200 psi)
Filter Element Collapse Pressure:20 bard (290 psid) – 4740 series
207 bard (3000 psid) – 4741 series
Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubricating fluids
Temperature Range:-29 ˚C to 120 ˚C (-20 ˚F to 250 ˚F)
60 ˚C (140 ˚F) maximum in HWCF or water glycols
3.4 bard (50 psid) - 4740 series
Non-bypass – 4741 series
2.4 bard (35 psid) – 4740 series
7 bard (100 psid) – 4741 series
Ductile iron head; steel bowls
Technical Specifications
4740/41 Series Filter Assemblies
Coralon® lube and hydraulic oil filters deliver
consistent, high level fluid system protection across all applications,
regardless of severity. Coralon filters feature BetaX(C) >1000 filter
efficiency, low pressure drop and long service life.
Features
- Flows
to 340 lpm (90 US gpm)
- Pressures
to 450 bar (6500 psi)
- Port
size: 1½”
Notes and Specifications
Filter Housing
- Fatigue
Pressure Rating
400 bar (5800 psi) per NFPA T2.6.1 R2-2001 Cat C/90
- Typical
Burst Pressure:
1,600 bar (23,200 psi)
- Filter
Element Collapse Pressure:
20 bard (290 psid) – 4740 series
207 bard (3000 psid) – 4741 series
- Fluid
Compatibility:
Compatible with all petroleum oils and most water glycols,
water-oil emulsions, and synthetic hydraulic and lubricating fluids
- Temperature
Range:
-29 ˚C to 120 ˚C (-20 ˚F to 250 ˚F)
60 ˚C (140 ˚F) maximum in HWCF or water glycols
- Bypass
Valve Setting:
3.4 bard (50 psid) - 4740 series
Non-bypass – 4741 series
- Indicator
Pressure Setting:
2.4 bard (35 psid) – 4740 series
7 bard (100 psid) – 4741 series
- Housing
Materials of Construction:
Ductile iron head; steel bowls