Applications
Railways, Machine tools
Category
Railways
Dielectric strength
U ? 250V: 1.45 kV / U ? 500V: 2 kV
terminal ground
Approval / conformity
EN60730-1/ EN60730-2-9: Typ 2.B.H
Vibration
5...25 Hz: ±1.6 mm
25...100 Hz: 4g
Media temperature
-30°C ... +350°C
Shock
50 g / 11 ms
Ambient temperature
Range ? +45°C: -30°C ... +50°C
Range +45°C ... +250°C: -30°C ... +70°C
Range > + 250°C: -10°C ... +70°C
(Important: Temperature at sensor may not exceed maximum sensortemperature)
Protection
IP65
Output signal
Floating change-over contact
Measuring range
-30°C ... +40°C to +70°C ... +350°C