im-tek.com

Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco MDT462F-1/2-2C-15/46-A Melt Pressure Transmitters
Dynisco MDT462F-M18-3,5C-50/46-A Melt Pressure Transmitters
Dynisco TDT463F Pressure Sensors
Dynisco PT-4624-1/2-5M-6/18-A Pressure Sensors
Dynisco TPT4634-2CB-6/18-S137A Pressure Sensors
Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT462E-1/2-1M-6/18 Pressure Sensors
Dynisco PT-242FM-20MPA-6/30 Pressure Sensors
Dynisco ECHO-MV3-PSI-R22-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers
Dynisco DYMT-S-1/2-PT100/4-5-15-G Melt Temperature Probe
Dynisco IDA 354 - 3,5C - 351 Pressure Transmitters
Dynisco TPT4634-1/2-5M-6/18-SIL2 Pressure Sensors
Dynisco IDA372-20-D08-D30/10 Pressure Transmitters
Dynisco PT462E-3M-6/18 Pressure Sensors
Dynisco PT462F-1/2-10M-6/18 Pressure Sensors
Dynisco 2291SA48K20BSMMAACAK Pressure Sensors
Dynisco TDA463-1/2-1M-15/46 Pressure Sensors
Dynisco MDT422T-1/2-3,5C-15/46A Melt Pressure Transmitters
Stenflex Type SF-21 DN 450 Expansion Joint
American Industrial AB-1003-FP Heat Exchanger
Gefran LT-M-0150-S 0000X000X0N Potentiometer
Anderson Greenwood MP2 Differential Pressure Manifold
Gefran LT-B-1200-S L000X000X00 Potentiometer
Gefran LT-H-0150-P 0000X000X00 Potentiometer
Ru-Steel RPD 10 RPD 6 Bolt Range with Spacer
American Industrial UCF-1260 Heat Exchanger
Olaer EHV10 Accumulator
Exheat FXS FXS Enclosure/Cabinet Heaters
Meister RVM/UM Flow Monitor For Liquids
Armatury L32.8 Butterfly Valve
Eurotherm 3504\Cc/Vl/1/Xx/10/1/Xxx/G/Rr/R4/Tk/Xx/Xx/Xx/Et/F2 Thristor Eurotherm 3504\Cc/Vl/1/Xx/10/1/Xxx/G/Rr/R4/Tk/Xx/Xx/Xx/Et/F2 Thristor
Kadant 995.639/ RX Rotary Union
Servomech MA 25 Mod A Screw Jack
Eurotherm P108/CC/VH/RRC/R/4C Process Control Eurotherm P108/CC/VH/RRC/R/4C Process Control
Grundfos MTR 45-5/5 A-F-A-HUUV Immersible Pump
Edur LUB100M170-2900 Single Stage Inline Pump
Hengstler RI59-O/1000EQ.7AKA-P0 Encoder
Alfa Laval 9611414651 VALVE LKB 152/6
Air Dimensions B141 B-Series Heated Head Dia-Vac® Diaphragm Pump
WARNER ELECTRIC PC Design Primary Clutch PTO Clutches
Faulhaber 1512U003SR 112:1 IE2-8 DC-Gearmotor
CKD GA400-8-P02 Differential Manometer