im-tek.com

Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco TPT463E-1/2-10M-6/18 Pressure Sensors
Dynisco MDT 462F-M18-7C-15/46 Melt Pressure Transmitters
Dynisco PT4624-5M-6/18-B628 Pressure Sensors
Dynisco TDT463F-1/2-7C-15/46-SIL2 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-A Melt Pressure Transmitters
Dynisco PT462E-7CB-6/18 Pressure Sensors
Dynisco ATC990-4-0-1-1-1-1-0-0-0 Process Controller
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco MDT422F-M10-2C-7,6/152-A Melt Pressure Transmitters
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco IDA354-3,5C-10V-S78B Pressure Transmitters
Dynisco UPR90030000000 Process Indicator
Dynisco TPT4634-5M-12/18 Pressure Sensors
Dynisco MDT462F-1/2-3,5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco UPR90030000000 Process Indicator
Dynisco PT291- S4-7K-4,8 /3.2R-B906. 6K Pressure Sensors
Dynisco MDT462F-1/2-3,5C-15/4... Melt Pressure Transmitters
Dynisco MDA462-1/2-1M-15/46 Pressure Sensors
Adler FZ4 DN80 HEATING JACKET VALVES
Control Techniques M600 10402700DU0100AN100 Control Module
Alfa Laval 9613359619 VALVE UNIQUE RV-ST 38/1.5 200 WELD NC REGULATING 0.8/BLASTED KV-4 EPDM
Emotron FDU69-003-20 Drive
Vulcanic 2388-15 Flange Immersion Heater
MBS MLI 76 6000 Industrial Crossflo
Alfa Laval 9612644017 BALL VALVE SBV-ISO-76-W/W-NC EPDM Ø104
PCM 90H12 Cavity Pump
Sitema KFHR 56 KFHR 056 71 Locking Unit
Topworx 7LG-13567B2 - SPDT, End Sensing, CSA GP, Green LED, 36Inch Cable, 316 Stainless Steel, Model 7L BriteLite GO Switch
Gefran LT-F-0800-P L000X000A0N Potentiometer
Hengstler RI59-O/2EQ.7AKB-F0 Encoder
HFB PDNI 315 Plummer Block Housing
Grundfos DMX 130-3D B-PVC/V/C-R-E1U3U3XEMAG Dosing Pump
Grundfos MTR 32-14/14 A-F-A-HUUV Immersible Pump
Stahl 8220/5-SL-SS45kW400V-T DOL Motor Starters, Star Delta Starter, Soft Starter
Siemens 6ES7516-3TN00-0AB0 Simatic S7-1500T CPU
Indexator 5214296 AV 14S Rotator
Vega VEGASON S62 Ultrasonic Sensor For Continuous Level Measurement
Vaisala HMT360 Series Intrinsically Safe Humidity and Temperature Transmitter
Stahl 8146/5241 Control Box
Cipriani L DN100 30 N Gaskets And Liners
Grundfos NK 150-225/238 AA1F1S3ESBQQEOW3 Pump
Gefran LT-M-0275-P L000X000A0N Potentiometer