im-tek.com

Dynisco ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors

Dynisco

Product Code: ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco 2291SA48K20BSMMAACAK Pressure Sensors
Dynisco ATC 770-0-3-3 Process Controller
Dynisco PT-242FM-35MPA-6/30 Pressure Sensors
Dynisco DYMT-S-1/2-PT100/4-15-15-G-1M-F13 Melt Temperature Probe
Dynisco ATC990-411111000 Process Controller
Dynisco ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors
Dynisco SPX2291SA56K09BSTTCCAZZ Pressure Sensors
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco MDA462-M18-3,5C-15/46 Pressure Sensors
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco PT160-4M Pressure Sensors
Dynisco 1480-1-0-0-0 Panel Indicator
Dynisco MDA460-1/2-5C-32 Pressure Sensors
Dynisco MDA462-1/2-7C-15/46 Pressure Sensors
Dynisco MDT462F-M18-3,5C-15/46-B171 Melt Pressure Transmitters
Dynisco MDT 462F 1/2 3.5C 15/46 Melt Pressure Transmitters
Dynisco MDT 462F-1/2-3,5C-15/46-T80 Melt Pressure Transmitters
Dynisco MDT462F-1/2-5C-15/46-SIL2 Melt Pressure Transmitters
Adalet D9SC-202008 Dust-ignition Proof Enclosures
Gefran LT-B-0075-P 0000X000N0N Potentiometer
Grundfos NK 125-180/171 AA1F1S3ESBQQEJW3 Pump
Grundfos CRN45-13-2 A-F-G-E-HQQE 3x400/690 50 HZ Multi Stage Pump
Holmatro HAHC100H15 Aluminium Hollow Plunger Cylinder
KSB HPKL050-032-160.1 EEBS Pump
Goldammer G3/4 ‘’-T-L300-T2-VA-2M12-TF70Ö-4-20mA Indicator
Ru-Steel F10 14” Elastics
Gefran LT-F-1000-S L000X000X0N Potentiometer
Edur BC25-202/0157-2900 Single Stage Close-Coupled Pump
Tecsis F1101 Hydraulic Compression Force Transducer
EISELE DPL118/1,I=3,Ø22MM Reducer
Coax DRV 20 Lateral Valve
HEIDENHAIN ROC 7390M 1110426-01 Angle Encoder With Integral Bearing
IME TM8P03120 Universal Transmitter For Obsolete D8w2
JVM MSA 50-60 Electro Magnetic Vibrator
Gefran LT-M-1350-P 0000X000X0N Potentiometer
Scherzinger 4050-710-ZK71-140 Titanium Gear Pumps 4050
Fristam FKL 150 Positive Displacement Pump
Ifm IF5896 IFK2004BFRKG/M/2LED/US-104-IRF Inductive Sensor
Emotron DSV15-23-3P2-20 Drive
Gefran LT-M-0800-P L000X000A00 Potentiometer
Hepco SSRSJ34CDRNS Linear Bearing
Wandfluh AH4D61B/F Control Valve