im-tek.com

Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco DYMT-S-M18-J-5-15-G-2M-A Melt Temperature Probe
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco FMMH-10M-6/30 Melt Monitor Indicator
Dynisco PT462E-15M-6/18 Pressure Sensors
Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco SPX 4222 N-A-00-B-17-CE-DD-A-AF-ZZ-GC8 Pressure Sensors
Dynisco MDT 422F-1/2-3.5C-15/46-B171-B173-SIL2 Melt Pressure Transmitters
Dynisco 462H0002 Pressure Sensor
Dynisco TPT4634-5M-12/18 Pressure Sensors
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco PT492-35MPA-15/46 Pressure Sensors
Dynisco PT462E-M18-5M-6/18 Pressure Sensors
Dynisco MDT422F-1/2-2C- 15/168-D83 Melt Pressure Transmitters
Dynisco PT303-5C Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco UPR90021000000 Process Indicator
Dynisco PT 160-4M-H11 Pressure Sensors
JVM JVC 276-1200 Unbalance Motor
Bühler GAS 222.15 MA Sample Gas Probe
Officine Orobiche 500-Z2 Flowmeter
Hengstler AX70/1212EK.72DPA-V0 Absolute Encoder
Alfamatic SA 1 Electric Cylinder
Gefran PC-M-0950 L000X000D00 Potentiometer
Faulhaber MCBL 3006 S AES Series Motion Controller
Metalwork 3683033U FR 200 1/2 50 08 SAC
Ele Fantini ALV Type Light Series Linear Actuators
Alfa Laval 9613360852 UNIQUE SSV TO DN-50 002 W 0.8/BLASTED EPDM SHUT OFF TANK OUTLET NC
MBS MLW 100 4 34 1 3000 Sanitary Mixflo Multitube
Vulcanic 3217-03 Screw Plug Immersion Heater
KSB ETN 040-025-160 FF CP1CGA2 B Pump
Vulcanic 3120-39 Screw Plug Immersion Heater
Gefran LT-B-0700-P L000X000N00 Potentiometer
DYSC-7-5-Y1F Shock Absorber DYSC-7-5-Y1F Shock Absorber
Elwa KVES-147 Preheater
Vulcanic 3218-02 Screw Plug Immersion Heater
Gefran LT-H-0300-P 0000X000X0N Potentiometer
Tempco (PTFE) 1-ELEMENT ROUND HEATER
Flovex BEM 1710 Fixed Straight Tubesheet Heat Exchangers
Dynisco MDT420F-1/2-1M-15-SIL2 Melt Pressure Transmitters
KSB UPHA293/06+HBC 303 6.0 SQMM S.D. Pump
Meister RVM/U-L4/2 Flow Monitor For Gases