im-tek.com

Dynisco ECHO-MV3-BAR-R21 Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21 Melt Pressure Transmitters
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21 Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco TPT463E-15M-6/18 Pressure Sensors
Dynisco MDT422F-1 / 2-3.5C-15/99-SIL2 Melt Pressure Transmitters
Dynisco UPR90030000000 Process Indicator
Dynisco PT160-4M-M11 Pressure Sensors
Dynisco PT4676-50MPA-10/18 Pressure Sensors
Dynisco ATC990-4-0-1-1-0-1-0-0-0 Process Controller
Dynisco PT4624-15M-12/18-SIL2 Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco UPR900-20000000 Process Indicator
Dynisco PT160A-4M-H88 Pressure Sensors
Dynisco MDA462-1/2-5C-15/46 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco UPR900-20000000 Process Indicator
Dynisco DYMT-S-1/2-PT100/4-15-15-G Melt Temperature Probe
Dynisco PT462E-1/2-10M-6/18 Pressure Sensors
Italvibras MVSI 15/80-S02 601341 Electric Vibrator
Gemü Gemü 807R40D 72114 168 4000 Variable Area Flowmeter
Meister 6002 Flowmeter
Aron Adh8C01I002+Ad3E01Cm003 Filter
Hengstler RI58-O/1000AS.41TE-E Encoder
KSB ETN 065-040-125 CC CP1CGA2 B Pump
KWD TK-N-AV 900 - 65 H7 - 70 H7 x 140 - KWN 29000 Coupling
ETP CLASSIC 85 Hub-Shaft Connection
Parker DF2070310QVT1HX1601 Duplex Filter
Tsurumi BER Series 3-PHASE / 50HZ Sewage Pumps
Westcode N2055MC280 Phase Control Thyristors-Capsule
Gefran LT-F-0175-S 0000X000X00 Potentiometer
Habasit TCF-50H Belt
Siebert SX502-840/03/0M-100/0A-E0 Display
Eurotherm EPACK-1PH/125A/500V/XXX/V2/XXX/XXX/TCP/XXX/XXXXX/ XXXXXX/GWE/XXX/XXXXXX////////// Controller Eurotherm EPACK-1PH/125A/500V/XXX/V2/XXX/XXX/TCP/XXX/XXXXX/ XXXXXX/GWE/XXX/XXXXXX////////// Controller
Grundfos NK 80-160/167 AA1F2AESBAQEQW1 Pump
Hydropa DS-112-350 / B / SS Pressure Switch
Ifm OW5021 OWI-BPKG/US-100 Infrared Temperature Sensor
Vega VEGACAL 63 Capacitive Rod Probe for Continuous Level Measurement
KSB MCPK125-080-400 CC MP2 A Pump
Gefran LT-B-0400-P 0000X000B00 Potentiometer
Ritz ASN 12 Support Type Current Transformer
Gefran PC-F-0050 L000X000X00 Potentiometer
LEROY SOMER CPLS Series Three-phase Induction Motors With Integrated Drive - 0.25kW to 7.5kW