im-tek.com

Dynisco ECHO-MV3-BAR-R21 Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-BAR-R21 Melt Pressure Transmitters
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-BAR-R21 Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco 463F0002 Pressure Transmitter
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Dynisco ECHO-MA4-BAR-R17-UNF-6PN-S06-NFL-NTR Melt Pressure Sensors
Dynisco PT160-5C Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco PT4624-15M-6/18-SIL2 Pressure Sensors
Dynisco PT4624-1/2-35MPA-6/18 Pressure Sensors
Dynisco PT462E-3M-6/30 Pressure Sensors
Dynisco MDT420F-1/2-1M-15-SIL2 Melt Pressure Transmitters
Dynisco MDA462-M18-3,5C-15/46 Pressure Sensors
Dynisco PT-242FM-35M Pressure Sensors
Dynisco PT-242FM-20MPA-6 Pressure Sensors
Dynisco ECHO-MA4-BAR-R23-UNf-6PN-S06-F18-NTR Melt Pressure Sensors
Dynisco DYMT-S-1/2-J10-F20 Melt Temperature Probe
Dynisco TDT463F Pressure Sensors
Dynisco TPT4634-1/2-5M-6/18-SIL2 Pressure Sensors
Dynisco MDT422F-1/2-3,5C-15/46 Melt Pressure Transmitters
Dynisco MDT463H-1/2-5C-15/46 Pressure Sensors
Topworx 75-13567H4 - SPDT, End Sensing, CSA GP, 144Inch PEEK Leads, 316 Stainless Steel, Model 75 GO Switch
Ham-let Hex NPT to SAE/MS Pipe Fitting
Schorch BN7 180M Three-phase-motor
Goldammer NTR 50-SR45-T1-A-FE-L370-01-L1/250/S-T60Ö-III-M12 Level - Temperature - Capillary tube – Regulator
Stahl TEF7000081 Thermostat
WARNER ELECTRIC GT 300 Clutch/Brakes
Emotron VFX48-013-54 Drive
Faulhaber SC 1801 F Series Speed Controller
Alfa Laval 9613320118 UNIQUE SSV 63.5 / 2½ INCH 200 WELDED 0.8/BLASTED SHUT OFF REGULATING MANUAL
Gefran LT-B-1350-S 0000X000N00 Potentiometer
Italvibras MVSI 10/5700-S02-TS 602351 Electric Vibrator with Split Cover
Micro Detectors SH4 / E-3EIC Safety
Habasit FNI-5ER 10 Food Belt
Böhmer FSK R 016.065 Ball Valve
Edur SUB700G148L-2900 Self-Priming Centrifugal Pump
Fisher RPE Electric Pilot Heater
MBS MLW 114 19 18 1 3000 Sanitary Mixflo Multitube
Friedrich FK 1750-8-7.8 Coupled Motor FK-Type
Rotork 400 Series Electric Actuator
Stahl 8220/5-SM-ES22kW400V-T DOL Motor Starters, Star Delta Starter, Soft Starter
Grundfos MTR45-10/2 A-F-A-HUUV 3X400/690 50HZ Immersible Pump
Mahle Pi 47040-010 70304333 Duplex Filter
Eaton Vickers (Danfoss) 02-137473-DDR 4535V50A381DD22R Hydraulic - Vane Pump
Grundfos NK 100-225/198 AA1F1S3ESBQQEHW5 Pump