im-tek.com

Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F30-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco TPT463E-10M-6/18 Pressure Sensors
Dynisco SPX4222-S-A-00-B-13-EZ-DD-C-AA-ZZ-Z017 Pressure Sensors
Dynisco EPR3-1.5M-6-TC-M561 Melt Pressure Sensors
Dynisco 2291NA48K13BUMMACAZZ Pressure Sensors
Dynisco PT482-1/2-15M-6/18-B379 Pressure Sensors
Dynisco PT462E-15M-6/18 Pressure Sensors
Dynisco MDT422T-1/2-3,5C-15/46A Melt Pressure Transmitters
Dynisco TPT-4634-3M-12/18 Pressure Sensors
Dynisco ATC990-4-0-1-1-1-1-0-0-0 Process Controller
Dynisco ECHO-MV3-BAR-R23-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco TPT4634-10M-12/18-SIL2 Pressure Sensors
Dynisco PT160A-4M-H88 Pressure Sensors
Dynisco MDT422F-1/2-3,5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco DYMT-S-1/2-J-10-15-G-0,7M-F20 Melt Temperature Probe
Dynisco DYMT-S-M18-J-7-15-G-2M-F13 Melt Temperature Probe
Dynisco TPT4634-7.5M-6/18 Pressure Sensors
Dynisco MDT422F-M10-2C-7,6/152-A Melt Pressure Transmitters
Dynisco PT462E-M18-7CB-6/18 Pressure Sensors
Hengstler AC58/1212EK.42PBA-A1-F Absolute Encoder
Adalet XJF-101410 Explosion Proof Control Enclosures
Faulhaber MC 5004 P Series Motion Controller
CD Automation REVO RT Loop
Gemü Gemü 695 50D38395E13/N Diaphragm Valve
Ritz GBW Current Transformers
Stahl 8573/15-311 Flange Socket With Extra Low Voltage
Scherzinger 5030-350-DM-220-2 Stainless Steel Gear Pumps 5030
Megger 210170 and 210600 Extended Range Insulation Resistance Tester
Alfa Laval TE67E111111240 PT: ´-1 to 0 bar 0,1% FS Clamp 1½",Cableoutlet,N/A
Stahl 7150/5-V11-H32AA-0500-0 Load Disconnect and Manual Transfer Switch
Vega EL 8 Conductive Rod Probe
Hengstler AC58/1212ES.71OLA Absolute Encoder
Gefran LT-B-1050-S L000X000B00 Potentiometer
Gefran LT-F-1050-S 0000X000N00 Potentiometer
Adler APM 500 PNEUMATIC ACTUATORS
Young-Massa VP_400X315 Slide Valve
Tempco QUARTZ 1- AND 3-TUBE STYLE HEATERS
Aryung ACP-180HF25 Coolant Pumps
Holmatro HFC 5 S 1.5 Cylinder
Festo DSBC-63-200-PPSA-N3 Cylinder Festo DSBC-63-200-PPSA-N3 Cylinder
Rhomberg AP430 Phase Sequence/Failure/Asymmetry Relay
Ebara CDXM 120/12 Centrifugal Pump
FSG PE-MH/1023-MU Series Tilt Angle Sensor