im-tek.com

Dynisco ECHO-MV3-PSI-R22-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R22-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R22-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco 149041000 Panel Indicator
Dynisco PT-242FM-20MPA-6/30 Pressure Sensors
Dynisco SPX2291SA56K09BSTTCCAZZ Pressure Sensors
Dynisco ECHO-MV3-BAR-R17-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco MDT422F-M10-2C-7,6/152-A Melt Pressure Transmitters
Dynisco 1480-1-0-0-0 Panel Indicator
Dynisco PT422A-10M-6/18 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco TPT463E-1/2-7,5M-6/18 Pressure Sensors
Dynisco DYMT-S-1/2-PT100/4-10-32-G Melt Temperature Probe
Dynisco UPR900-2-1-0-1-0-0-0-0 Process Indicator
Dynisco TDT463F-1/2-3,5C-15/46 Pressure Sensors
Dynisco MDT422F-1/2-3,5C-23/46-A Melt Pressure Transmitters
Dynisco SPX 4222 N-A-00-B-17-CE-DD-A-AF-ZZ-GC8 Pressure Sensors
Dynisco TDT432F-1/2-5C-46/46-S147-SIL2 Pressure Sensors
Dynisco ATC990-401111000 Process Controller
Dynisco PT160-4M-H88 Pressure Sensors
Dynisco PT415D-5M-6-B314-B173 Pressure Sensors
Coax PCD 10 DR High Pressure Lateral Valve
Hengstler AC58/1214EK.42DNR Absolute Encoder
SETTIMA GR47-2V-028-F3AC9-O-DX POMPA A VITI ELICOIDALI
Martens MLR120 Evaluation Electronics
Gestra PRS 8-F cycling timer
Festo DSBF-C-32-40-PPVA-N3-R Cylinder Festo DSBF-C-32-40-PPVA-N3-R Cylinder
Eurotherm Ch00740A Main Assurance Eurotherm Ch00740A Main Assurance
Scherzinger 5040-350-DM-75-6 Hastelloy (R) Gear Pumps 5040
Amg Pesch SAD-180°-45 Double-Piston Quarter Turn Actuator
Gefran LT-B-1000-S L000X000A0N Potentiometer
ETP MINI R-12 Hub-Shaft Connection
Aoip PHP 601 High Accurate Dual Input Reference Thermometer For RTDs and Thermocouples
Inoxihp SD1 Separator for Branched Mounting
Fybroc Series 8500 Vertical Turbine Pump
KSB ETN 080-065-315 GC P1CGA3 B Pump
Hengstler AC58/0012AK.42SGD Absolute Encoder
Gefran LT-M-1100-P L000X000N0N Potentiometer
Gefran LT-M-0225-S L000X000N0N Potentiometer
Stenflex Type SF-11 DN 25 Expansion Joint
MBS MLM 76 n 12 12 1 1500 Multiflo Heat Exchanger
Officine Orobiche PL-18 Flow Alarm Switch
Hengstler RI59-O/4096EQ.7AIB Encoder
Gefran LT-H-1200-P 0000X000A00 Potentiometer
Bühler 222.20 DENOX Sample Gas Probe GAS