im-tek.com

Dynisco ECHO-MV3-PSI-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R23-UNF-6PN-S06-F18-TCJ Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco FMMH-10M-6/30 Melt Monitor Indicator
Dynisco 224200000141 Pressure sensors
Dynisco TDA463-1/2-1M-15/46 Pressure Sensors
Dynisco MDT462F-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco 224200000142 Pressure Sensors
Dynisco PT291- S4-7K-4,8 /3.2R-B906. 6K Pressure Sensors
Dynisco IDA354-3,5C-10V-S78B Pressure Transmitters
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-F30-NTR Melt Pressure Transducers
Dynisco MDA422-1/2-35-15/46 Pressure Sensors
Dynisco MDA-460-1/2-1M-15 Pressure Sensors
Dynisco PT462E-M18-7CB-6/18 Pressure Sensors
Dynisco MDT420CAN-/2-7C-15-HA51 Melt Pressure Transmitters
Dynisco MDT462F-1/2-5C-15/46-T80-SIL2 Melt Pressure Transmitters
Dynisco MDT462F-M18-3,5C-50/46-A Melt Pressure Transmitters
Dynisco MDT462H-1/2-5C-15/46 Melt Pressure Transmitters
Dynisco UPR900-2-1-1-1-0-0-0-0 Process Indicator
Dynisco TPT 4634-3,5C-15/45 Pressure Sensors
Dynisco PT462E-7CB-6/18 Pressure Sensors
MBS MLI 114 1500 Industrial Crossflo
Vulcanic 2115-08 Screw Plug Immersion Heater
Scherzinger 4030-710-DM-110-2-Exd Stainless Steel Gear Pumps 4030
MBS MLD 76 4 22 1 3000 Mixflo Multitube Demontable Heat Exchanger
Mts Sensor LHTRB00U01201DE02
Gefran LM-L-A-0800 L000X000X Linear Position Transducer
Gefran LT-H-0950-P L000X000X0N Potentiometer
FIP Italy RVAT Series DN 10÷100 Sediment Strainer
Gefran LT-M-0300-S 0000X000A0N Potentiometer
Goldammer NTR 50-SR40-T2-A-FE-L370-01-L1/250/S-T70Ö-III-M12 Level - Temperature - Capillary tube – Regulator
Topworx 7LR-13527B3 - SPDT, End Sensing, CSA GP, Red LED, 72Inch Cable, 303 Stainless Steel, Model 7L BriteLite GO Switch
Hengstler AC58/1212EK.72OLA Absolute Encoder
Friedrich FD 1750-8-7.8 Vibrator Motor with steel bearing cover FD-Type
Valco LINEAR – S Continuous Level Meter
Scherzinger 3030-110-B-DM-12-8-Exd Stainless Steel Gear Pumps 3030
Alfamatic SA 10 Electric Cylinder
Vulcanic 2029-42 Flange Immersion Heater
Hengstler AC58/1212EK.42CLB Absolute Encoder
Gefa SERIES DG H 3-Piece Ball Valve
Gestra NRGS 15-1
PULS CP20.241-C1 1-phase DIN Rail Power Supply
Topworx 73-14537H2 - 5/8Inch, SPDT, End Sensing, 36Inch PEEK Leads, CSA GP, 303 SS Hi-Pressure Enclosure, Model 73 GO Switch
Goyen 3-8V7110-336 Pilot Valve Enclosure
Eurotherm 3208/CC/VH/LRDX/R/4CL/G/ENG/ENG/XXXXX/XXXXX/XXXXX/XXXXXX/X/X/X/X/X/X/X/X Temperature Controller Eurotherm 3208/CC/VH/LRDX/R/4CL/G/ENG/ENG/XXXXX/XXXXX/XXXXX/XXXXXX/X/X/X/X/X/X/X/X Temperature Controller