im-tek.com

Dynisco ECHO-VT1-MPA-R22-M14-6PN-S06-F18-TCK Melt Pressure Transducer

Dynisco

Product Code: ECHO-VT1-MPA-R22-M14-6PN-S06-F18-TCK Melt Pressure Transducer
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-VT1-MPA-R22-M14-6PN-S06-F18-TCK Melt Pressure Transducer

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.  

Recommended Products For Dynisco


Dynisco PT462E-M18-7CB-6/189 Pressure Sensors
Dynisco MDA462-1/2-1M-15/46 Pressure Sensors
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Dynisco DYMT-F-M18-PT100/4-0-15-G Melt Temperature Probe
Dynisco 1490-4-0-0-0-0 Panel Indicator
Dynisco 2291NA48K13BUMMACAZZ Pressure Sensors
Dynisco MDA460-1M-15 Pressure Sensors
Dynisco TPT484-5M-6/18-B379 Pressure Sensors
Dynisco MDT462F-1/2-3.5C-15/46-T80-SIL2 - Melt Pressure Transmitters
Dynisco 1390-2-3 Temperature Indicator
Dynisco TPT463L-1/2-10M-6/18 Pressure Sensors
Dynisco TPT463E-5CB-6/18 Pressure Sensors
Dynisco TDT432F-1/2-5C-46/46-S137-SIL2 Pressure Sensors
Dynisco TPT 4634-3,5C-15/45 Pressure Sensors
Dynisco TPT4634-2CB-6/18-S137A Pressure Sensors
Dynisco 224200000142 Pressure Sensors
Dynisco PT160-4M-M11 Pressure Sensors
Dynisco ATC 770-0-3-3 Process Controller
Flucom RLY 50DN Valve
Woerner VPA-D Progressive distributor
Edur NUB500C140L-2900 Single Stage Close-Coupled Pump
Ayvaz HBJ Hygienic Steam and Pure Steam Generator
HFB BTL 3156 K Two Bearing House
Indexator 5006385 GV 6 A Rotator
Dunkermotoren BGE6015 A Controller
Gestra SBO31
Eaton Vickers (Danfoss) PVQ10-A2R-SE1S-20-C21-12 Piston Pump
KSB BPI322/05D+UMAISOL 150-13/22 A Pump
Knf FEM 1.09 KP SM-2 Diaphragm Dosing Pump
Imtron DAQSoft Measurement Data Software
Ru-Steel RP 260 RP 6 Bolt Range Without Spacer
Zpa Pecky MOPED Series Electric Actuator
Hengstler RI59-O/1024EQ.7AIB-F0 Encoder
Gefran LT-M-0700-P 0000X000X0N Potentiometer
Viking Pump 475 SERIES Pumps
Friedrich F 300-4-4.0 Vibrator Motor F-Type
HFB GOS 634 Plummer Block Housing
Goyen 12BWJ2-ENBNT-6081 Solenoid Valve
KSB UPHA293/03+HBC 153 2.5 SQMM S.D. Pump
Italvibras MVTX 15/5000-G/D 601574 Explosion Proof Screen Vibrator
KSB MCPK200-200-250 GB NP2 A Pump
American Industrial SRCS-1760 Heat Exchanger