im-tek.com

Dynisco ECHO-MV3-PSI-R21-UNF-6PN-F30-NTR Melt Pressure Transducers

Dynisco

Product Code: ECHO-MV3-PSI-R21-UNF-6PN-F30-NTR Melt Pressure Transducers
Brand: Dynisco



GET OFFER: info@imtek.com.tr

Description for Dynisco ECHO-MV3-PSI-R21-UNF-6PN-F30-NTR Melt Pressure Transducers

·         2 year warranty and 60 years of Dynisco industry experience·         Accuracy better than ±0.5%·         TiAlN diaphragm coating is standard·         mV/V, 0-10VDC, or mA outputs available·         Integral temperature sensor option·         Available in configurations that fit most extruder applications·         1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability·         Alternative fill model available  Operating Principle The Dynisco EchoTM Melt Pressure Sensors are used to make pressure measurements of molten polymers up to 752°F (400°C). These models incorporate a 350?Ohm, bonded foil strain gage Wheatstone Bridge. This proven technology provides an output of 0?3.33 mV/V, & 4?20mA, 05?VDC and 0?10VDC proportional to melt pressure (within the specified error band). Most models include an internal shunt calibration ("Rcal") function that is used to simulate a signal of 80% of full scale. This eliminates the need for a cumbersome calibrated pressure source when scaling associated instrumentation. Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole per Figure 1. Gauge Plug, P/N 200908, is available for this purpose. Before installing make sure that mounting hole is clear of material. Dynisco Cleaning Tool Kit, P/N 200100, should be used. To prevent galling, lightly coat transducer threads with a high temperature anti?seize material. An adequate seal, in a properly machined and maintained mounting well, is obtained with 100 in?lbs. mounting torque. The maximum torque recommended is 500 in?lbs. The electronics housing should be secured, with the optional mounting bracket (P/N 200941), in an area where the ambient temperature will not exceed 185°F (85°C). (Mounting bracket not supplied with EchoTM models.)Wiring Use shielded cable. Attach cable shield to ground at one end only. NOTE: DYNISCO cable assemblies are constructed with shield wired to transducer mating connector, so do not attach shield to instrument. Output Supply Voltage mV/V 10 Vdc (12 Vdc max) mA 14?36 Vdc Vdc 16?36 Vdc Start?Up Bring system to operating temperature with no pressure. For mA units, remove adjustment access screw and adjust Zero Output potentiometer. For mV/V units, zero adjustment must be handled by downstream indicator. Make sure that there is sufficient "soak time" to assure that any material at the tip of the transducer is molten before extruder drive is started. Removal Transducer should only be removed when polymer is hot and liquid. Wipe tip with a soft cloth immediately. The melt pressure transducer must be removed before using an abrasive material or wire brush to clean the extruder barrel. Clean the mounting well before attempting to reinstall the transducer with Dynisco Mounting Well Cleaning Tool Kit, P/N 200100. Thermocouple Thermocouples ( Type J or K) in a rigid stem are optionally available. The Type J (iron?constantan) and Type K is a T/C junction just behind the flush diaphragm at the tip of the transducer. For the most accurate temperature measurement of the melt stream, use a separate immersion?type thermocouple, such as Dynisco TB422 fixed depth series or (G)RMT adjustable models. The thermocouple assembly can be removed by loosening the set screw on the side of hex assembly and pulling the T/C probe, carefully, straight out, without twisting. Replacement assemblies are available. When installing the thermocouple probe assembly, align the slot with the pressure capillary tube and press into snout until top of probe shoulders flush against snout. Lock in place with set screw.Warranty This Dynisco product is warranted under terms and conditions set forth in the Dynisco Web Pages. Go to www.dynisco.com and click on “Warranty” at the bottom of any page for complete details.

Recommended Products For Dynisco


Dynisco UPR900-2-1-1-1-0-0-0-0 Process Indicator
Dynisco MDA460-1M-15 Pressure Sensors
Dynisco PT4624-35MPA-6/18-SIL2 Pressure sensors
Dynisco MDT462F-1/2-3.5C-15/46-SIL2 Melt Pressure Transmitters
Dynisco ECHO-MV3-PSI-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco ATC990-4-1-1-1-0-1-0-0-0 Process Controller
Dynisco 149041000 Panel Indicator
Dynisco PT492-35MPA-15/46 Pressure Sensors
Dynisco TDT463F-1/2-7C-15/46-SIL2 Pressure Sensors
Dynisco ECHO-MV3-BAR-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco ECHO-MV3-MPA-R21-UNF-6PN-S06-F18-NTR Melt Pressure Transducers
Dynisco 4622NA00P24CEDDAAFZZGC7 Pressure Sensor
Dynisco IDA334-1M Pressure Transmitters
Dynisco MDT420CAN-/2-7C-15-HA51 Melt Pressure Transmitters
Dynisco MDT462F-1/2-3,5C-15-91-SIL2 Melt Pressure Transmitters
Dynisco FMMH-10M-6/30 Melt Monitor Indicator
Dynisco PT462E-5M-6/18 Pressure Sensors
Dynisco 224200000142 Pressure Sensors
Alfa Laval 9612628534 LKB 76/3
Olaer EHVF 5-300/94 Kit
Alfa Laval 9612075240 VALVE LKB-2 DN65 DIN M/M FPM 316L
Knf N 035.3 Series Vacuum Pumps with IP20 Motor
Elcis 758S A01 - Single turn abs. parallel -SSI - analogic encoder
Faulhaber 0308H003B Brushless DC-Servomotor
Greisinger GOX100-T-LACK Air Oxygen Meter Device
Gefran WPG-A-W-0350-N 0000X000X00X0XX Magnetostrictives
HFB GOS 610 Plummer Block Housing
Ringfeder TNT 2420 Safety Coupling
Faulhaber 2642W018CXR DC-Micromotor
Gefran LT-B-0110-P L000X000X00 Potentiometer
Gefran LT-B-0350-S L000X000X00 Potentiometer
Faulhaber 2444S024B Brushless DC-Servomotor
Mahle Pi 3711-013 77810385 Duplex Filter
Eaton Vickers (Danfoss) EEA PAM 335 D 33 Power Amplifier
Ebara AGC 1.50 T Self-Priming Centrifugal Pumps
Vulcanic 2389-54 Flange Immersion Heater
Edur CV32/9-1-2900 Multi-Stage Inline Pump
PCM EcoMoineau™ C 05C12S Progressive Cavity Pump
Gefran LT-H-0350-S 0000X000N0N Potentiometer
Italvibras MVSI 15/550E-S02 6E1373 Increased Safety Electric Vibrator
Hengstler AC58/1214EQ.72VDS Absolute Encoder
Zeppelin ZWV 80 Diverter Valve