Product Name: Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Brand: Dynisco
Product Code: TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Tags: Dynisco
Sensors
Pressure
TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Dynisco Pressure
TDT432F-1/2-3,5C-46/46-S137-SIL2
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2
TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure
Dynisco Sensors
Dynisco Pressure Sensors
TDT432F-1/2-3,5C-46/46-S137-SIL2 Sensors
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors
Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Sensors
Pressure Sensors
Are you interested in the product Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors from manufacturer Dynisco with code TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!
Get Offer With E-Mail: info@im-tek.com
Get a offer for Dynisco TDT432F-1/2-3,5C-46/46-S137-SIL2 Pressure Sensors from our live support team now!
Installation for media temperature up to 400°C Flexible capillary between rigid stem and housing Electrical built-in calibration Various high level outputs 4-20 mA, 2-wire 0-10 V DC, 3/4-wire and other volt output signal ranges Performance Characteristics Pressure Range: 0-17 bar to 0-2000 bar Accuracy: MDT422F ±0.5% FSO (up to 50 bar ±1% FSO); Repeatability: MDT422F ±0.1% FSO (up to 50 bar ±0.2% FSO); MDT462F ±0.2% FSO Resolution: Infinite Maximum Overload (without in"uencing operating data): 2x pressure range for range 1000 and 1400 Burst Pressure: 6x pressure range max. 3000 bar Material in Contact with Media: 15-5 PH SST (Mat. No. 1.4545) DyMax® coated Electrical Characteristics Confguration: 4-arm Wheatstone bridge strain gage Internal Shunt Calibration: 80% of full scale ±1% Output Signal: 2-wire 4-20 mA Supply Voltage: 12-36 Vdc Zero Balance: ±1% Rezero Initiation: Locally via zero potentiometer, or remotely via short circuit between pins “D” and “F” Range Calibration 80% FSO: “Short circuit” between connections pins “E” and “F” at the sensor or externally from the control room Load Resistance: Maximum 1200 at 36 Vdc Maximum 500 at 24 Vdc Isolation Resistance: 1000M* at 50 Vdc Temperature Influence Diaphragm: Max. Temperature: 400ºC Zero Shift (due to temperature change): MDT422F X < 0.2 bar/10ºC MDT462F X < 0.4 bar/10ºC Housing: Max. Temperature: 85ºC Zero Shift (due to temperature change): ±0.2% FSO/10ºC Sensitivity Shift (due to temperature change): MDT422 X ±0.1% f.s.v./10ºC up to 50 bar ±0.2% f.s.v./10ºC MDT462 X ±0.4% f.s.v./10ºC Approvals &Self Certifications CE: Directive 2004/108/EC ISO