Aoip CALYS 150 Multifunction Calibrator
Product Code:CALYS 150
Description
CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument. CALYS 150 does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator integrated into ACL500 modem) and thermistors. Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS 150 complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and makes advanced data exploitation and full data traceability easier. High performances for CALYS 150, for advanced use:
· Temperature Up to 0.005 % RDG
· Resistance Up to 0.006 % RDG and 50 K? range
· Current: Up to 0.007 % RDG and 100 mA range + Loop Supply 24 V
· Voltage: Up to 0.005 % RDG and 50 V range
· Frequency: Up to 0.01 % RDG and 100 KHz range
· Pressure: With an external pressure module (comparison calibration with a pressure pump)
Using this user-friendly instrument, calibration tasks can be quickly carried out over the whole process chain. Take the 900 g documenting process calibrator to the field with you during the whole week with 10 calibration procedures stored in the device. Run the procedure after connecting the probes to the instrument (Easy connect system®) and save the results for onsite easy and quick calibration. Back to the office, you can then upload the data on a computer in order to issue customized calibration certificates with dedicated calibration software DATACAL. IP 54, fully protected by an antichoc rubber holster, CALYS 150 integrates "easyconnect" terminals and a wide backlite display that makes it easy to use in any severe or dark conditions. When used with an external pressure module (ref. ACL433), CALYS 150 can measure and simulate pressure (comparison calibration with a pressure pump). CALYS 150 has also the capability to drive baths and dry-blocks when associated with the specific cable (ref. ACL600).
Easy connection system
Connect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors. Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples. This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top.
CALYS series, 4 models from basic use to advanced performances
Specifications
CALYS 50
CALYS 75
CALYS 100
CALYS 150
Top accuracy
200 ppm
130 ppm
50 ppm
Temperature accuracy
Thermocouples (14) RTDs (12)
0.013% RDG for Tc K 0.012% RDG
0.01% RDG for Tc K 0.01% RDG
0.005% RDG for Tc K 0.006% RDG
DC current + Loop supply 24 V
Range Accuracy
50 mA 0.0175% RDG
100 mA 0.007% RDG
DC voltage
Range Accuracy
50 V IN / 20 V OUT 0.013% RDG
50 V 0.013% RDG
50 V 0.010% RDG
50 V 0.005% RDG
Frequency
Range Accuracy
20 KHz IN / 10 KHz OUT 0.005% RDG
100 KHz 0.01% RDG
Resistance
Range Accuracy
4000 ? 0.012% RDG
4000 ? 0.010% RDG
50 K? 0.006% RDG
Pressure
Range Accuracy
Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG
Compliance to standards
21 CFR Part 11
NADCAP Heat treatment AMS 2750
Additional functions
Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function
Additional functions
Switch test Calibration of transmitters
Additional functions
Comparison calibration HART: Digital calibration and data transfer Calibration of thermistors
Software
DATACAL calibration software for configuration and data management
Memory
10,000 data stored and recalled on screen as curve or list
Technical Specifications
CALYS 150 field documenting multifunction calibrator is the top instrument
of the range. It is the perfect tool for advanced process maintenance and use
on test bench in all industries. Suitable for all field and lab measurements,
it can simultaneously measure and generate over two isolated channels various
signals of temperature, resistance, process, pressure and frequency in one
single instrument. CALYS 150 does not only work as a simulator (IN / OUT) but
also as a dual channel thermometer (IN / IN) to perform
comparison calibration. It calibrates HART transmitters (HART
communicator integrated into ACL500 modem) and thermistors.
Providing extended functionalities (temperature simulation,
scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS
150 complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and
makes advanced data exploitation and full data traceability easier. High
performances for CALYS 150, for advanced use:
·
Temperature Up to 0.005 % RDG
·
Resistance Up to 0.006 % RDG and 50 K?
range
·
Current: Up to 0.007 % RDG and 100 mA
range + Loop Supply 24 V
·
Voltage: Up to 0.005 % RDG and 50 V
range
·
Frequency: Up to 0.01 % RDG and 100 KHz
range
·
Pressure: With an external pressure
module (comparison calibration with a pressure pump)
Using this user-friendly instrument, calibration tasks can be quickly
carried out over the whole process chain. Take the 900 g documenting process
calibrator to the field with you during the whole week with 10
calibration procedures stored in the device. Run the procedure after
connecting the probes to the instrument (Easy connect system®) and save the
results for onsite easy and quick calibration. Back to the office, you can then
upload the data on a computer in order to issue customized calibration
certificates with dedicated calibration software DATACAL. IP 54, fully
protected by an antichoc rubber holster, CALYS 150 integrates
"easyconnect" terminals and a wide backlite display that makes it
easy to use in any severe or dark conditions. When used with an external
pressure module (ref. ACL433), CALYS 150 can measure and simulate pressure
(comparison calibration with a pressure pump). CALYS 150 has also the
capability to drive baths and dry-blocks when associated with the specific
cable (ref. ACL600).
Easy connection system
Connect your
probes by simply pushing on the terminal top and insert wires of up to 3 mm or
10 AWG diameter and compensated thermocouple connectors. Wires are held tight
between two brass plates ensuring thermal stability and a very good cold
junction compensation for thermocouples. This system also enables 4 mm banana
plugs and security connectors to be connected on the terminal top.
CALYS series, 4 models from basic use to advanced performances
|
Specifications |
CALYS 50 |
CALYS 75 |
CALYS 100 |
CALYS 150 |
|
|
Top accuracy |
200 ppm |
130 ppm |
50 ppm |
||
|
Temperature accuracy |
Thermocouples (14) RTDs (12) |
0.013% RDG for Tc K 0.012% RDG |
0.01% RDG for Tc K 0.01% RDG |
0.005% RDG for Tc K 0.006% RDG |
|
|
DC current + Loop supply 24 V |
Range Accuracy |
50 mA 0.0175% RDG |
100 mA 0.007% RDG |
||
|
DC voltage |
Range Accuracy |
50 V IN / 20 V OUT 0.013% RDG |
50 V 0.013% RDG |
50 V 0.010% RDG |
50 V 0.005% RDG |
|
Frequency |
Range Accuracy |
20 KHz IN / 10 KHz OUT 0.005% RDG |
100 KHz 0.01% RDG |
||
|
Resistance |
Range Accuracy |
4000 ? 0.012% RDG |
4000 ? 0.010% RDG |
50 K? 0.006% RDG |
|
|
Pressure |
Range Accuracy |
|
Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG |
||
|
Compliance to standards |
|
|
|
21 CFR Part 11 |
|
|
|
|
|
NADCAP Heat treatment AMS 2750 |
||
|
Additional functions |
Advanced data exploitation: Scaling, relative measurement, simulation of
ramps and steps, synthetizer, square root, statistical functions Transmitter
function |
||||
|
Additional functions |
|
Switch test Calibration of transmitters |
|||
|
Additional functions |
|
|
|
Comparison calibration HART: Digital calibration and data transfer
Calibration of thermistors |
|
|
Software |
|
DATACAL calibration software for configuration and data management |
|||
|
Memory |
|
10,000 data stored and recalled on screen as curve or list |
|||