Cemb
Cemb T7P Angular Measuring Sensor
Product Code:T7P
Description
The transducer T7 -P is used for the valve position monitoring of steam turbines.
the output voltage is proportional to the angle of rotation of the shaft
Detecting systemLinear potentiometerWorking principleMeasuring of an angular position of the potentiometer, pin referred to the fix position of the pick-upMeasuring range0÷350° ±1°Potenziometer characteristResistance = 1000 OhmLinearity = ±0,05% ÷ ±0,5%Sensitivity42,8mV/°/+15VdcPower supply+ 15 Vdc, GNDMechanical connectiondia. 6,35 +0/-0,1: s.steel shaftElectrical connectionConnector MIL C-5015, serial 3102/16, std.suppliedCase materialAluminiumEnvironm. Operation condit.Temperature = -50°C ÷ +100°CHumidity = max 95% not condensingOutside = IP55 EN60529/10.91Vibrations = max.20g/2KHzMaintenanceAnyTechnical Specifications
The transducer T7 -P is used for the valve position monitoring of steam turbines.
the output voltage is proportional to the angle of rotation of the shaft
| Detecting system | Linear potentiometer |
| Working principle | Measuring of an angular position of the potentiometer, pin referred to the fix position of the pick-up |
| Measuring range | 0÷350° ±1° |
| Potenziometer characterist | Resistance = 1000 Ohm |
| Linearity = ±0,05% ÷ ±0,5% | |
| Sensitivity | 42,8mV/°/+15Vdc |
| Power supply | + 15 Vdc, GND |
| Mechanical connection | dia. 6,35 +0/-0,1: s.steel shaft |
| Electrical connection | Connector MIL C-5015, serial 3102/16, std.supplied |
| Case material | Aluminium |
| Environm. Operation condit. | Temperature = -50°C ÷ +100°C |
| Humidity = max 95% not condensing | |
| Outside = IP55 EN60529/10.91 | |
| Vibrations = max.20g/2KHz | |
| Maintenance | Any |