Zimmer
Zimmer ARP Series AR160P Axis Compensation Modules
Product Code:AR160P
Description
ARP50P
AR63P
AR80P
Connecting flange according EN ISO 9409-1TK 160Installation Height28 [mm]Horizontal deviation +/-2 [mm]Horizontal deviation +/-1 [°]Vertical deviation2 [mm]Vertical deviation1 [°]Bending moment on stop Mysee diagram [Nm]Twisting moment on stop Mrsiehe Diagramm [Nm]Horizontal displace force to stop FHsiehe Diagramm [N]Vertical displace force to stop FVsee diagram [N]Centering force when locking3000 [N]Repetition accuracy Horizontal +/-0.05 [mm/°]Repetition accuracy Vertical +/-0.05 [mm/°]Air volume per cycle14 [cm³]Operating pressure min.1 [bar]Operating pressure max.8 [bar]Operating temperature min.5 [°C]Operating temperature max.+80 [°C]Moment of inertia115 [kg/cm²]Weight5.6 [kg]Deflection hoirontal +/-2 / 1 [mm/°]Defletion vertical2 / 1 [mm/°]Recommended handling weight60 [kg]Technical Specifications
ARP50P
AR63P
AR80P
| Connecting flange according EN ISO 9409-1 | TK 160 |
| Installation Height | 28 [mm] |
| Horizontal deviation +/- | 2 [mm] |
| Horizontal deviation +/- | 1 [°] |
| Vertical deviation | 2 [mm] |
| Vertical deviation | 1 [°] |
| Bending moment on stop My | see diagram [Nm] |
| Twisting moment on stop Mr | siehe Diagramm [Nm] |
| Horizontal displace force to stop FH | siehe Diagramm [N] |
| Vertical displace force to stop FV | see diagram [N] |
| Centering force when locking | 3000 [N] |
| Repetition accuracy Horizontal +/- | 0.05 [mm/°] |
| Repetition accuracy Vertical +/- | 0.05 [mm/°] |
| Air volume per cycle | 14 [cm³] |
| Operating pressure min. | 1 [bar] |
| Operating pressure max. | 8 [bar] |
| Operating temperature min. | 5 [°C] |
| Operating temperature max. | +80 [°C] |
| Moment of inertia | 115 [kg/cm²] |
| Weight | 5.6 [kg] |
| Deflection hoirontal +/- | 2 / 1 [mm/°] |
| Defletion vertical | 2 / 1 [mm/°] |
| Recommended handling weight | 60 [kg] |