Esam E1200-T1 Network Power Analyzer

Technical Documentation

Technical Datasheets / Product Documentations

WhatsApp
Brand
CategoryOthers
Product NameEsam E1200-T1 Network Power Analyzer
Product CodeE1200-T1
Visa – Secure credit card payment acceptedMastercard – Secure credit card payment acceptedAmerican Express – Secure credit card payment acceptedDiners Club – Secure credit card payment acceptedDiscover – Secure credit card payment accepted

Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.

Product Description

Esam products, including Esam E1200-T1 Network Power Analyzer, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. As an authorized trading partner, Imtek Engineering offers genuine Esam parts at competitive prices. Even if Esam E1200-T1 Network Power Analyzer is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.

Network Power Analyzer
DATI TECNICI
tensione nominale Vn: 230V fase/neutro, 400V fase/fase campo di misura tensione: 0 … 1.2 Vn
corrente nominale d’ingresso In: 5A campo di misura corrente: 0 … 1.2 In
sovraccarico permanente: 1.5Vn, 2In sovraccarico istantaneo (1 sec.): 2Vn, 20 In
rapporto TA esterno impostabile: 1 … 99999 rapporto TV esterno impostabile: 1 … 99999
tempo di media valori misurati: ½ periodo AC … 1 sec classe di precisione per tensioni, correnti e potenza attiva: ±
0,2% della lettura (5 ... 100% del campo di misura, 45 … 65 Hz) coefficiente di temperatura: ±0,01%/°C
interfaccia seriale RS485: 1200 … 115200 baud, Modbus RTU acquisizione dati veloce: tipico 40 variabili in circa 40 msec
interfaccia Ethernet: 10 Mbit/s, connettore RJ45, protocolli HTTP (web server integrato) e Modbus/TCP (per acquisizione dati, max
3 connessioni simultanee) alimentazione ausiliaria standard: 115-230Vac 50/60Hz oppure
in opzione: 24V o 100V o 400V ±15% - consumo 4VA alimentazione ausiliaria opzionale: 12Vdc ±15% oppure
20…60Vac/dc 60…265Vac/dc (Morsetti : [V0] - e [V2] +) consumo: 4W conforme a EN61010-1 (sicurezza) e EN61326 (EMC)
isolamento fra ingressi V e ingressi I:
4kV (60sec,50Hz) isolamento fra due ingressi I:
4kV (60sec,50Hz) isolamento fra ingressi e altri morsetti:
4kV (60sec,50Hz) isolamento fra uscite e alim. ausiliaria:
2kV (60sec,50Hz) isolamento fra due uscite:
1kV (60sec,50Hz) temperatura di funzionamento:
-10° … +55°C temperatura di impiego:
+5° … +40°C temperatura di immagazzinamento:
-30° … +70°C temperatura di riferimento:
+20°C
TECHNICAL DATA
nominal voltage Vn: 230V phase/neutral, 400V phase/phase input voltage range: 0 ... 1.2Vn
nominal input current : 5A input current range: 0 … 1.2 In continuous overload: 1.5Vn, 2In
instantaneous overload (1 sec): 2Vn, 20In programmable external TV ratio: 1 ... 99999
programmable external TV ratio: 1 ... 99999 averaging time interval: ½ AC period ... 1 sec
accuracy (voltage, current, active power): ± 0,2% of reading (5 ... 100% of input range, 45 … 65 Hz)
temperature coefficient: ±0,01%/°C RS485 serial interface: 1200 ... 115200 baud, Modbus RTU
fast data acquisition: typically 40 variables in about 40 msec Ethernet interface: 10 Mbit/s, RJ45 connector, HTTP protocol
(embedded web server) and Modbus/TCP (for data acquisition, max 3 simultaneous connections)
syandard auxiliary power: 115-230Vac 50/60Hz or in option:
24Vac or 100Vac or 400Vac ± 15% - consumption: 4VA optional auxiliary power: 12Vdc ±15% or 20...60Vac/dc
60...265Vac/dc (input terminals: [V0] - and [V2] +) consumption: 4W complies with EN61010-1 (safety) and EN61326 (EMC)
Insulation V inputs to I inputs:
4kV (60sec,50Hz) Insulation between two I inputs:
4kV / 60sec, 50Hz Insulation, inputs to any other terminal:
4kV (60sec 50Hz) Insulation outputs to aux.power:
2kV (60sec,50Hz) Insulation between two outputs:
1kV (60sec,50Hz) operating temperature range:
-10° … +55°C calibrated temperature range:
+5° … +40°C storage temperature rang:
-30° … +70°C reference temperature:
+20°C
SCHEMI D’INSERZIONE - DIMENSIONI D’INGOMBRO / WIRING DIAGRAMS - OVERALL DIMENSIONS
Circuito trifase a 4 fili (3 TA)
Circuito trifase a 3 fili (2 TA, inserzione ARON)
Three-phase 4 wires circuit (3 CT)
Three-phase 3 wires circuit (2 CT, ARON insertion)
Circuito monofase
Dimensioni d’ingombro
Single-phase circuit
Overall dimensions
montaggio su profilato DIN EN50022-35 / rail DIN EN50022-35 mounting
ATTENZIONE TENSIONE PERICOLOSA Rischio di shock elettrico e ustioni. L’apparecchio deve essere installato da personale qualificato.
Togliere tensione prima di eseguire ogni tipo di lavoro e osservare le istruzioni per l’uso. (per altre eventuali informazioni ved. www.esam.biz)
WARNING HAZARDOUS VOLTAGE Can cause electrical shock and burns. This equipment must be installed by qualified persons only.
Disconnect power before proceeding with any work and observe the operating instructions (see www.esam.biz for other possible info).
20010 Bareggio (MI) Italy – Via S. Pietro, 10 Elettronica Strumenti Apparecchiature Misura
Tel. +39 0290361297 – Fax +39 0290362314

Frequently Asked Questions

Frequently asked questions about Esam E1200-T1 Network Power Analyzer by Esam. Imtek Engineering is ready to assist you in sourcing Esam E1200-T1 Network Power Analyzer from Esam in United States.

Imtek Engineering sources genuine Esam products through trusted supply channels and supplies them to customers in United States at competitive prices.