Product Name: ESN Type 8480-KAG2 Evaluation Unit
Brand: ESN
Product Code: Type 8480-KAG2
Tags: ESN
ESN Type 8480-KAG2
ESN Unit
Type 8480-KAG2 Evaluation Unit
Type 8480-KAG2 Evaluation Unit
ESN Unit
ESN Type Unit
ESN Type 8480-KAG2 Unit
ESN Type Evaluation
8480-KAG2 Evaluation Unit
Evaluation
Type 8480-KAG2 Unit
ESN Type
Type 8480-KAG2
Evaluation Unit
Evaluation Unit
ESN Type
8480-KAG2 Evaluation
Artikel: 410110
Evaluation Unit
Are you interested in the product ESN Type 8480-KAG2 Evaluation Unit from manufacturer ESN with code Type 8480-KAG2? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!
Get Offer With E-Mail: info@im-tek.com
Get a offer for ESN Type 8480-KAG2 Evaluation Unit from our live support team now!
Evaluation unit – Non-contact overhead wire contactThe type 8480-KAG2 evaluation unit is used for signal evaluation for the TLC 4 non-contact overhead wire contact. Both the isolating stage and the signal evaluation section are incorporated in a plastic housing. Technical data Dimensions WxHxD 150/73/113 mm Housing material Terminal plate: Polycarbonate Lower part: ABS Attachment Plastic-reinforced glassfibre Weight approx. 1.4 kg Attachment 2 holes to be drilled as per the drilling template, standard carrying rail as per DIN EN 50022 Type of protection Housing: IP 40; terminals: IP 10 Ambient temperature -20°C to +70°C Supply voltage terminal 31 (N/L-); terminal 32 (L/ L+) AC 230 V ? 8480 1- DC 18 V - 80 V ? 8480 5- Special voltages on request Current drawn approx. 10 VA /5 W Sensor connection resistant to short-circuits, terminal 21 (-); terminal 22 (+) Open-circuit voltage: DC 24 V± 5% max. current approx. 200 mA Signal inputs: 2 antivalent inputs, terminals 19/20 max. current < 35 mA (limited) Input divider 1 input pulse = 1 output pulse ? 8480 11 / ? 8480 51 2 input pulses = 1 output pulse ? 8480 12 / ? 8480 52 Input memory max. 15 (30) signal pulses can be stored Relay outputs 2 changeover contacts (zero- potential) terminals 11 - 16 Voltage Current cos ? AC 250 V 4.0 A > 0.7 DC 80 V 1.0 A ohmic load Signal duration 0.6 s (in the case of multiple signals, breaks likewise 0.6 s), other timings such as 0.5 s to special order Error 1 changeover contact (zero-poten- tial) terminals 4 - 6 Voltage Current cos ? AC 250 V 4.0 A > 0.7 DC 80 V 1.0 A ohmic load Can be switched between working current and quiescent current Ext. acknowledgement Remote acknowledgment (and local) terminals 8 - 9 Voltage at the terminals DC 15 V; 1k < 20 mA Test voltage 4 kVeff