ESN Type 8513 Control Unit
ESN
Product Code: Type 8513
Brand: ESN
GET OFFER: info@imtek.com.tr
Description for ESN Type 8513 Control Unit
Control Unit with/without pulse extension and running-time limitationThe Type 8513 control unit serves the purposes of power supply, remote control, function monitoring, and switch-position reporting on switch drive motors based on the 3-lead principle (inwards lead, outwards lead, and return lead). Technical Data Dimensions W/H/D = 100/70/115 mm Housing ABS / polystyrol Fastening 2 drilled holes as in drilling diagram Safety category Housing IP 40; Terminals IP 10 Ambient temperature -20°C to +60°C Fuse / breaker as required (standard = 6.3A) Command buttons 2 (for “On” and “O?”) Contact connection max. AC 250V, 5.0A Indicators 2 light-emitting diodes Colours: red, yellow, green or to customer’s specification (standard: “On” = red, “O?” = green) 1 zero-potential switch contact for “On”, 1 for “O?” U ? AC 250V; I ? 2A; P ? 500 VA Remote control con- nections Consumption approx. 250 mW Voltage DC 24 V (19 - 34 V) ? 8513 01 / ? 8513 11 DC 60 V (38 - 86 V) ? 8513 02 / ? 8513 12 DC 110 V (88 -120 V) ? 8513 03 / ? 8513 13 Timings Impulse extension = running time limitation Standard: approx. 10 seconds (adju- stable, 1-15 seconds) Test voltage Field side against indicator contact and Field side against control side 4 kVe? (1 minute) without pulse exten- ? 8513 0- sion and running-time limitation with pulse extension ? 8513 1- and running-time limitation Ordering Information Type Order No. 8513 01 310200 8513 02 310202 8513 03 310204 8513 11 310201 851312 310203 851313 310205Recommended Products For ESN