Product Name: ESN Type 8582 Switching Amplifier
Brand: ESN
Product Code: Type 8582
Tags: ESN
ESN Type 8582
ESN Type 8582 Switching Amplifier
Switching
ESN Type
Type Amplifier
8582 Amplifier
Type Amplifier
Type Switching
ESN 8582 Switching Amplifier
Type 8582 Switching
Switching Amplifier
Type Switching Amplifier
ESN 8582
Type 8582 Switching Amplifier
8582 Switching
ESN Type 8582 Amplifier
Type 8582
ESN Type Amplifier
ESN Amplifier
Artikel: 420200
Switching Amplifier
Are you interested in the product ESN Type 8582 Switching Amplifier from manufacturer ESN with code Type 8582? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!
Get Offer With E-Mail: info@im-tek.com
Get a offer for ESN Type 8582 Switching Amplifier from our live support team now!
Switching amplifier with electronic and relay outputThe type 8582 isolating switching amplifier converts binary signals from sensors into switching signals that meet practically all requirements in the sector of electric railways or allow simple adaptation. Technical data Dimensions see figure, WxHxD 145x70x112 mm Housing ABS / polycarbonate Attachment 2 drilled holes as per the drilling template Standard carrying rail in accordance with DIN EN 50022 Type of protection Housing: IP 40; terminals: IP 20 Connections 2 X 2.5 mm2 solid as per DIN 46288 or 2 x 1.5 mm2 with sleeve Ambient temperature -20°C to +60°C Supply voltage Terminal 31 (L1); terminal 27 (L2) DC 150 V to DC 900 V AC 115 V to AC 600 V Power drawn max. 8 W Sensor connection resistant to short-circuits, termi- nal 11 (*); terminal 12 (-) Nominal voltage DC 12 V Max. current (1k) approx. 25 mA Switching point 11 mA ± 1 mA Hysteresis approx. 4.5 mA Initiation delay approx. 1 s (other values on request) Relay output 1 make-type contact (zero-potenti- al, terminals 2,4 (K1) with varistor protective switching Voltage max. DC 900 V Current max. 3A Power max. 50 W Relay output 1 make-type contact (zero-potential), terminals 8,9 (K2) AC 250 V 4.0 A cos? > 0.7 DC 120 V 1.0 A ohmic load Electronic output Terminals 14,15 (K3), resistant to short-circuiting Nominal voltage DC 12 V Current max. 20 mA Max. current (Ik) approx. 35 mA Test voltages Supply voltage ? inputs/outputs 6 kVe? Output terminal ? inputs/outputs 6 kVe? Output K2 ? sensor/K3 4 kVe? There is no galvanic separation between the sensor connection and the electronic switching output. Accessories see brochure sheets 8432, 8433 Temperature monitor and 8434 Ordering information Type 8582 00 Part No. 420200