Fast delivery from GERMANY to worldwide
Wide Range of PaymentsMultiple payment options
VisaMastercardAmerican ExpressDiners ClubDiscover
  1. Products
  2. Fife
  3. Sensor
  4. Fife SE-46C Digital Line Guide Sensor

Fife SE-46C Digital Line Guide Sensor

Technical Documentation

Technical Datasheets / Product Documentations

WhatsApp
Brand
CategorySensor
Product NameFife SE-46C Digital Line Guide Sensor
Product CodeUnspecified
Visa – Secure credit card payment acceptedMastercard – Secure credit card payment acceptedAmerican Express – Secure credit card payment acceptedDiners Club – Secure credit card payment acceptedDiscover – Secure credit card payment accepted

Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.

Product Description

Fife products, including Fife SE-46C Digital Line Guide Sensor, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. As an authorized trading partner, Imtek Engineering offers genuine Fife parts at competitive prices. Even if Fife SE-46C Digital Line Guide Sensor is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.

Digital Line Guide Sensor
2-5
COMMISSIONING OF D-MAX
2.1. Setting ASC thresholds
D-MAX OI-N operator interface:
∙ Select menu 1y.3.y6.2 (Job Settings ASC ASC Threshold 1 (Pos)) ∙ Set ASC threshold 1 (pos) to 90.0%
∙ Select menu 1y.3.y6.3 (Job Settings ASC ASC Threshold 2 (Neg)) ∙ Set ASC threshold 2 (neg) to −90.0%
2.2. Switching on the ASC function
D-MAX OI-N operator interface:
∙ Select menu 1y.3.y6.1 (Job Settings ASC ASC State) ∙ Set the ASC State to ON
3. Setting the polarity and gain
3.1. Setting the polarity
Note:
Connection to X5: job with y = 'J' Connection to X9: job with y = 'K
The guiding direction (polarity) must be checked depending on the mechanical installation direction of the system and adjusted
if necessary.
D-MAX OI-N operator interface:
∙ Select menu1.y.3.y8 (Job Settings Polarity) ∙ Set the polarity
3.2. Setting the gain
The gain must be set optimally.
D-MAX OI-N operator interface:
∙ Select menu 1.y.3.y3 (Job Settings Gain) ∙ Set the gain