Enclosure
Below flange
IP 21
Above flange
IP 50
Ambient temperature
–30 - +60° [–22 - +140°F]
Max. force on handle
1000 N static
Basic
Supply voltages
U+
≤30 V
Proportional functions
P
5 KΩ ±50%
R1 & R2
P × 0.225 ±1%
Max signal current
15 μA (1 mA peak)
Max direction switch load for all proportional functions
30 VDC / 2mA
Max push button load
30 VDC / 50mA
Note: There are no electronics built in to the Basic level module.
Standard and Extended
Supply voltages
UDC, U+
10-30 V
Max ripple
5%
Current consumption
≈150 mA
Signal voltage Us
Us
Min → Max
0.25 → 0.75
U+
Neutral position
0.50
Signal load in neutral position
Load type
PVE
Other
Load impedance
>6 kΩ
>15 kΩ
Signal current at max movement
@ UDC = 12 V
Us - 0.5 × U+ 6 kΩ
± 0.6 mA
Us
15 kΩ
0.2 → 0.6 mA
@ UDC = 24 V
± 1.2 mA
0.4 → 1.2 mA
Signal current in neutral position
@ UDC = 12 V
± 0 mA
0.4 mA
@ UDC = 24 V
± 0 mA
0.8 mA
Inverter
Non inverted
Output signal = Us
Inverted
Output signal =
-1 × (Us – 0.5×U+) + 0.5×U+
Push buttons and directions switches for all proportional functions
Max load
0.6 A
Push 7 & Push 8
Max load
30 VDC / 50 mA
Neutral position switch
Max load
3 A
Extended only
Signal regulation Us
Us
Min (50%)
0.37 → 0.63
at 100% movement
U+
Max (200%)
0.25 → 0.75
at 50% movement
Dead band compensation
Us
Min
0.00
U+
Max
0.06