HEIDENHAIN LB 382 Single SectionSealed Linear Encoder
Product Code:LB 382 Single Section
Description
Specifications
LB 382 up to ML 3 040 mm
Measuring standard
Coefficient of linear expansion
Rustproof steel scale tape with AURODUR graduation, grating period 40 µm
?therm 10 x 10–6 K–1
Accuracy grade
±5 µm
Measuring length ML* in mm
Single-section housing
440 640 840 1040 1240 1440 1640 1840 2040 2240 2440 2640 2840 3040
Reference mark* LB 382
LB 382 C
Selectable by selector plate every 50 mm, standard setting: 1 reference mark in the center
Distance-coded
Interface
? 1 VPP
Signal period
40 µm
Diagnostics interface
Analog
Cutoff frequency –3 dB
? 250 kHz
Electrical connection
Separate adapter cable (1 m/3 m/6 m/9 m) connectible to mounting block
Cable length1)
? 150 m
Voltage supply
without load
DC 5 V ±0.25 V/< 150 mA
Traversing speed
? 120 m/min (max. acceleration in measuring direction ? 60 m/s2)
Required moving force
? 15 N
Vibration 55 Hz to 2000 Hz
Shock 11 ms
? 300 m/s2 (EN 60 068-2-6)
? 300 m/s2 (EN 60 068-2-27)
Operating temperature
0 °C to 50 °C
Protection EN 60 529
IP53 when mounted according to the instructions and mounting information
IP64 if compressed air is connected via DA 400
Mass
1.3 kg + 3.6 kg/m measuring length
* Please select when ordering
1) With HEIDENHAIN cable
Technical Specifications
Specifications |
LB 382 up to ML 3 040 mm |
|
Measuring standard Coefficient of linear expansion |
Rustproof steel scale tape with AURODUR graduation, grating period 40 µm ?therm 10 x 10–6 K–1 |
|
Accuracy grade |
±5 µm |
|
Measuring length ML* in mm |
Single-section housing 440 640 840 1040 1240 1440 1640 1840 2040 2240 2440 2640 2840 3040 |
|
Reference mark* LB 382 LB 382 C |
Selectable by selector plate every 50 mm, standard setting: 1 reference mark in the center Distance-coded |
|
Interface |
? 1 VPP |
|
Signal period |
40 µm |
|
Diagnostics interface |
Analog |
|
Cutoff frequency –3 dB |
? 250 kHz |
|
Electrical connection |
Separate adapter cable (1 m/3 m/6 m/9 m) connectible to mounting block |
|
Cable length1) |
? 150 m |
|
Voltage supply |
DC 5 V ±0.25 V/< 150 mA |
|
Traversing speed |
? 120 m/min (max. acceleration in measuring direction ? 60 m/s2) |
|
Required moving force |
? 15 N |
|
Vibration 55 Hz to 2000 Hz Shock 11 ms |
? 300 m/s2 (EN 60 068-2-6) ? 300 m/s2 (EN 60 068-2-27) |
|
Operating temperature |
0 °C to 50 °C |
|
Protection EN 60 529 |
IP53 when mounted according to the instructions and mounting information IP64 if compressed air is connected via DA 400 |
|
Mass |
1.3 kg + 3.6 kg/m measuring length |
|
* Please select when ordering 1) With HEIDENHAIN cable | |