Serial InterfaceBaudrate
50 bps to 921.6 kbps (supports non-standard baudrates)
Connector
Terminal block
Isolation
TCC-100I/100I-T: 2 kV (-I model)
No. of Ports
2
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Serial Standards
RS-232, RS-422, RS-485
Terminator for RS-485
N/A, 120 ohms, 120 kilo-ohms
Serial SignalsRS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND
Power ParametersInput Current
TCC-100/100-T: 85 mA @ 12 VDC
TCC-100I/100I-T: 150 mA @ 12 VDC
Input Voltage
12 to 48 VDC
No. of Power Inputs
1
Overload Current Protection
Supported
Power Connector
Terminal block (for DC models)
Power Consumption
TCC-100/100-T: 85 mA @ 12 VDC
TCC-100I/100I-T: 150 mA @ 12 VDC
Physical CharacteristicsHousing
Metal
Dimensions
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
IP Rating
IP30
Weight
148 g (0.33 lb)
Installation
DIN-rail mounting (with optional kit), Wall mounting
Environmental LimitsOperating Temperature
Standard Models: -20 to 60°C (-4 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and CertificationsEMC
EN 55032/24
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
Environmental Testing
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
Safety
EN 60950-1, IEC 60950-1
Vibration
IEC 60068-2-6
MTBFTime
3,017,857 hrs
Standards
Telcordia (Bellcore), GB