im-tek.com

Gestra LRGS 15-1

Gestra

Product Code: LRGS 15-1
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra LRGS 15-1

Technical Data Service pressure PN25: 25 barg at 224 °C Mechanical connection Screwed ¾", ISO 228-1 Screwed ¾" NPT (optional) Materials Screw-in electrode body: 1.4571, X6CrNiMoTi17-12-2 or 1.4404, A 479 316 L (for NPT thread) Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 Electrode rod insulation: PTFE Terminal box: Polycarbonate Measuring length & length of installation 200, 300, 400, 500, 600, 800, 1000 mm Input 1 Input for resistance thermometer, e. g. TRG 5-53, measuring insert Pt 100 Measuring range 100 to 10000 µS/cm at 25 °C or 50 to 5000 ppm at 25 °C Setpoint Adjustable between 100 and 10000 µS/cm or 50 to 5000 ppm MAX limit Adjustable between 100 and 10000 µS/cm or 50 to 5000 ppm Switching hysteresis Controller output: –10 % of the adjusted setpoint MAX limit: –3 % of the adjusted MAX limit Temperature coefficient Tk (if a resistance thermometer Pt 100 is connected) 1.6 – 3.0 % per °C, adjustable in steps of 0.1 Supply voltages 230 V, +10 / –15 %, 50-60 Hz 115 V, +10 / –15 %, 50-60 Hz (optional) Power consumption 5 VA Fuse External slow-blow fuse 63 mA at 230 V External slow-blow fuse 125 mA at 115 V Output 3 Volt-free relay contacts 5 A 230 V AC / 30 V DC cos ? = 1 (IEC 61810) Provide contactor with inference suppressor (RC combination). Contact material: AgNi 0.15 Indicators and adjustors 1 Four-digit, seven-segment indicator, red, for showing the actual value (X) / setpoint (W) and status & malfunction messages 2 Amber LEDs for indicating the actual value (X) / setpoint (W) 1 Red LED for indicating the MAX limit 2 Green LEDs for indicating “Valve OPEN / CLOSED” 4 Pushbuttons for parameter settings Cable entry / Electrical connection Cable glands with integrated cable clamp, 3 x M 16 x 1.5 1 Four-pole screw-type terminal strip for mains connection 1 Three-pole screw-type terminal strip for connecting the continuous blowdown valve 1 Three-pole screw-type terminal strip for MAX limit The terminal strips can be detached; conductor size 1.5 mm2 4 Terminal lugs for connecting the resistance thermometer Protection IP 65 to DIN EN 60529 Protection class 2 (protective insulation) Weight Approx. 1.5 kg Ambient temperature when system is switched on: 0 ° ... 70 °C, during operation: -10 ... 70 °C Transport temperature –20 ... +80 °C (< 100 hours), defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Storage temperature –20 ... +70 °C, defrosting time of the de-energized equipment before it can be put into operation: 24 hours. Relative humidity max. 95%, no moisture condensation Site altitude max. 2000 m

Recommended Products For Gestra


Gestra UNA38
Gestra MK45A-2
Gestra BAE46 Continuous Blowdown Valve Reaktomat
Gestra NRG16-41.1
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra KDL13
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra LRR1-53-URB50
Gestra LRGT 16-2 KART
Gestra NRS1-51
Gestra GSV442
Gestra VZ20 Rail Hook
Gestra ZK29-ASME
Gestra CW41-VALVE SELECTION
Gestra CW44K
Gestra BA47 Continuous Blowdown Valve Reaktomat
Gestra BK45
Gestra MK25-2S
JVM JVC 134-46 Unbalance Motor
Parker HFD1320QEBM3KD100A1 Duplex Filter
Conductix Wampfler M-Line 0330 Series I-Beam Cable Trolleys
FIP Italy SSENV Series DN 65÷100 Easyfit Ball Check Valve
KSB ETNY065-040-200 SGSDT25LA2 B Pump
FIP Italy VKDGV Series DN 65÷100 DUAL BLOCK® 2-way Ball Valve
Stauff 4020PP-SIP-AF-W3
Grundfos MTR 1S-13/13 A-W-A-HUUV Immersible Pump
Edur NUB700F148-2900 Single Stage Close-Coupled Pump
Gefran LT-F-0700-P 0000X000B00 Potentiometer
JVM JVC 276-800 Unbalance Motor
Hengstler AC58/0010EQ.46PGY Absolute Encoder
FIP Italy DKLUIV Series DN 15÷65 DIALOCK® 2-way Diaphragm Valve
Parker 15P102QHVE2KS1221 Duplex Filter
Metalwork 4469007UA V3V 300 SOL. MICRO 24V 50/60HZ W/END P.
Bimba SS-090.011-DW Original Line® All Stainless Steel
WARNER ELECTRIC H110 Series Hydraulic Multidisc Clutch
Gefran LT-B-0050-P 0000X000A00 Potentiometer
Grundfos DMX 75-4 B-SS/V/SS-X-E1A1A1XEMNG Dosing Pump
Tempco HEATING TAPE
Gefran LT-H-0600-S 0000X000B00 Potentiometer
Ru-Steel F10 16” Elastics
Meister RVO/U-2/12 Flowmeter
Hengesbach KERAMESS KS101 Flush-mounted pressure and level transmitter