im-tek.com

Gestra NRG16-39S

Gestra

Product Code: NRG16-39S
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra NRG16-39S

Description The level electrode NRG 16-38S, NRG 16-39S is used in conjunction with level switch NRS 1-50 for water level limiting and level monitoring in steam boilers and (pressurised) hot-water installations on board of seagoing vessels, mobile offshore platforms or river boats. Water level limiters switch off the heating when the water level falls below the set minimum level (low water). Function The level electrode NRG 16-38S is an equipment combination consisting of 1 level electrode NRG 16-11 (water level limiter) and 1 level transmitter NRGT 26-1S (continuous level monitoring). The level electrode NRG 16-39S is an equipment combination consisting of 2 level electrodes NRG 16-11 (water level limiter) and 1 level transmitter NRGT 26-1S (continuous level monitoring). Water level limiter NRG 16-11 / NRS 1-50 The water level limiter is an equipment combination consisting of one or two level electrode(s) NRG 16-11 and one level switch NRS 1-50. When the water level falls below the low level, the level electrode is exposed and a low level alarm is triggered in the level switch NRS 1-50. This switchpoint “Low water level (LW)” is determined by the length of the electrode tip. After the de-energizing delay has elapsed, the two output contacts of the level switch NRS 1-50 will open the safety circuit for the heating. The equipment has a factory set default de-energizing delay of 15 seconds to compensate for the movements of the ship. The operation of the level electrode NRG 16-11 is based on the conductive measuring principle using the electrical conductivity of the water for signalling water level. The self-monitoring function ensures that an alarm will also be triggered if the electrode insulation is contaminated or has developed a leak or if there is a malfunction in the electrical connection. The level electrode is installed inside steam boilers or (pressurized) hot-water systems. The protective tube mounted on site ensures correct functioning. Continuous level monitoring NRGT 26-1S The level transmitter NRGT 26-1S is a compact-type system consisting of a capacitance level electrode with integrated level transmitter. The equipment works according to the capacitance measurement principle and provides a level proportional measuring current of 4-20 mA. The level transmitter continuously monitors the liquid level in steam boilers or hot-water installations. 

Recommended Products For Gestra


Gestra NRG16-40
Gestra GAV54F
Gestra VK14
Gestra RK41 DN65 PN6-16 Non-return valve
Gestra DRT
Gestra MPA110
Gestra TRG5-53
Gestra SBO11
Gestra ZK29-ASME
Gestra MK25-2
Gestra RK49
Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra BK36A-7
Gestra BK28DN15 PN100 Steam Trap
Gestra TRV5-40
Gestra RK86 A DN200 PN40/CL300 Non-Return Valve
Gestra BW31
Gestra CB26A
American Industrial FBF-1272-SP Heat Exchanger
Stahl 9470/33-16-10 Digital Input/Output Module for Zone 2
PULS CS10.241-S1 1-phase DIN Rail Power Supply
American Industrial AB-2006-FP Heat Exchanger
KSB MCPK200-150-400 GB NP2 A Pump
Eltra EMB5L5L5L5L.1V ADAPTOR ENCODER I/O 5VDC 4OUTPUTS
Barksdale UNS-VA 1/8 NPT-VA27 (formerly BLS 1750) Level Switch ?NPT Stainless Steel
Micro Detectors CT1/AP-2H Proximity Sensor
Gefran LS-A-N-0-Z-0550-0-000X-A-0-0X Linear Position Transducer
Jungmichel S 3.0P3S Sensor
Alfamatic AP 13125 Power Group
Stauff SP-130-F-10-B/4 Filter Element
Adler FA2 DN50 PN40 316L N828053 Valve
Elcis 958H A01 - Single turn abs. parallel -SSI - analogic encoder
Knf N 035.2 Series Compressors with IP20 Motor
Beka P605 MULTI LINE OIL PUMPS
Kelvion XL Series Cooling Tower
Gefran LT-B-1100-P 0000X000X00 Potentiometer
BUCHER MTKAVC*2M22 42481916 Valve
Standart Pump SNV-B Process Pumps (Sump Design)
Ru-Steel RSP 0400 RSP 6 Bolt Range with Spacer and Adaptors
Vulcanic 2115-03 Screw Plug Immersion Heater
Gefran LT-M-0650-S 0000X000A0N Potentiometer
Faulhaber 1331T024SR DC-Micromotor