im-tek.com

Gestra NRG17-40

Gestra

Product Code: NRG17-40
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra NRG17-40

Description The level electrodes NRG 1...-40 work according to the conductivity measurement principle and detect the min. level in electrically conductive liquids: ? One level alarm with one switchpoint Use level electrode NRG 1...-40 in combination with level switch NRS 1-40 or NRS 1-40.1 and/or other system components. The NRG 1...-40 in conjunction with its associated control equipment constitutes a water level limiter with periodic self-testing routine (SMART function) in accordance with TRD 604, sheet 1 and 2 and EN regulations. The level data are transferred from the electrode NRG 1...-40 to the control unit via a CAN bus using the CANopen protocol.Function The electrode operation is based on the conductive measuring principle using the electrical conductivity for signalling liquid levels. Some liquids are conductive, which means that they allow an electric currrent to flow through them. For the safe functioning of this device a minimum conductivity of the liquid to be monitored is required. The conductivity measurement method can detect two conditions: electrode rod submerged or exposed, meaning switchpoint reached (or exceeded) or not yet reached. Before installation, the electrode rod must be cut to length to give the required low-level alarm and effect the consequent cut-out of the burner circuit. The system incorporates an additional electrode that provides automatic monitoring of the electrical resistance path between the measuring electrode and the earth. When the measured value falls below the admissible resistance value the burner shutdown is endorsed by interruption of the burner protection circuit. At regular intervals, the level electrode NRG 1...-40 sends a data telegram to the controller NRS 1-40. The data transfer is effected by means of a CAN bus according to DIN ISO 11898 adopting the CANopen protocol. One controller type NRS 1-40 can be used for two level electrodes NRG 1...-40 (low-level limiter arrangemant). 

Recommended Products For Gestra


Gestra NRS1-54
Gestra BK29
Gestra BB1ASME Dual-Plate Check Valve
Gestra UNA14P
Gestra LRS1-7
Gestra NRS1-52
Gestra MK45-2 PN40 DN25 KONDENSTOP
Gestra AK45 Automatic drainage valve
Gestra TRG5-55
Gestra BB2ASME Dual-Plate Check Valve
Gestra LRG16-9
Gestra SMK22-51
Gestra ZK213
Gestra VKP10 Steam Trap Testing Equipment VAPOPHONE
Gestra LRG16-4
Gestra NRG16-19
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra BK28DN15 PN100 Steam Trap
Grundfos CRE 1-4 A-FGJ-A-E-HQQE Multi Stage Pump
Faulhaber 1724T024SR DC-Micromotor
Ayvaz CV10/S2 Check Valve
Gemü Gemü 857R25D 72114 144 1600 Variable Area Flowmeter,
ACL SRL 161 2/2 Direct Acting Dry
Abo Valve 2E-5490B 050 LEVER
VIMARC FNZ 430-4 Vibrator motors
Emotron VFX69-013-54 Drive
Cipriani G 900+N Gaskets And Liners
Gefran LT-M-0600-S L000X000N0N Potentiometer
Ham-let Male Elbow Let-Lok Tube Fitting
Eaton Vickers (Danfoss) DG5V 2CT MUC 730 NG16/220VAC/300 LT Valve
Vorwald 00/12184/6/0609 20.8X14X30MM Shaft
Ebara CMA 0,50 T Centrifugal Pump
American Industrial UCS-2048 Heat Exchanger
Wilkerson R08-02-F000 Regulator
NSD VRE-P062FAC Single-turn Type ABSOCODER Sensor
Alfa Laval 9613001055 UNIQUE SEAT CLEAN DN-50/50 12-90 EPDM BLASTED (LOWER BAL.)(NONE CIP)
MBS MLD 139 19 18 1 3000 Mixflo Multitube Demontable Heat Exchanger
Aignep 101 MALE SOCKET
Gestra BK212-F91
Nuovafima 1.OM.2.A.E AAFV 335 homogenizer gauges
Gefran LT-B-0350-P 0000X000A00 Potentiometer
Vulcanic 2188-58 Flange Immersion Heater